Specifications - Omron D4GS-N Datasheet

Safety-door switch
Table of Contents

Advertisement

Specifications

Approved Standards
Agency
Standard
TÜV Rheinland
EN60947-5-1
GS-ET-15
UL (see note)
UL508
CSA C22.2 No. 14
Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN1088
EN60204-1
Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Rated operating current (I
)
e
Rated operating voltage (U
)
e
Note: Use a 10-A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
C300
Rated voltage
Carry current
120 VAC
240 VAC
Q300
Rated voltage
Carry current
125 VDC
250 VDC
D4GS-N
File No.
J2051125
(Direct opening:
approved)
E76675
AC-15
DC-13
0.75 A
0.27 A
240 V
250 V
Make
15
2.5 A
7.5
Make
0.55
2.5 A
0.27
Current (A)
Break
1.5
0.75
Current (A)
Break
0.55
0.27
Voltage (VA)
Make
Break
1,800
180
Voltage (VA)
Make
Break
69
69