Omron D4C Datasheet page 22

Enclosed switch
Table of Contents

Advertisement

Mounting
A maximum of 6 Switches may be group-mounted. In this case, pay
attention to the mounting direction so that the convex part of the
group-mounting guide on one Switch fits into the concave part of the
guide on the other Switch as shown in the figure below. For group
mounting, the mounting panel must have a thickness (t) of 6 mm min.
Group Mounting
Group-mounting guide
(Front: convex
Rear: concave)
16 mm
Group-mounting guide
(Front: convex
Rear: concave)
If the mounting panel is warped or has protruding parts, a malfunc-
tion may result. Make sure that the mounting panel is not warped and
has even surfaces.
Mounting Holes
Two, 5.2-dia. or M5 screw holes
Use a Switch with a rubber cap when using the plunger type in an
environment where malfunction is possible due to environmental
conditions such as dust or cutting chips which may not allow reset-
ting.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C032-E1-08
F-30
Enclosed Switch
Mounting panel
t
In the interest of product improvement, specifications are subject to change without notice.
D4C
Do not expose the Switch to water exceeding 70 C or use it in steam.
When the D4C is used in a circuit of a device to be exported to
Europe, classified as Overvoltage Class III as specified in IEC664,
provide a contact protection circuit.
Tighten each screw to a torque according to the following table.
No.
Type
1
M5 Allen-head bolt
2
M3.5 head mounting screw
3
M5 Allen-head bolt
Note: By removing the two screws from the head, the head direction
can be rotated 180 . After changing the head direction, re-tight-
en to the torque specified above. Be careful not to allow any for-
eign substance to enter the Switch.
Micro-load Models (D4C-4, -5, -6)
Switching Range
Micro-load models can be used for switching in the range shown
below.
5mW
0.16mA
30
24
Switching
range for
micro-load
models
12
Switching
not possible
in this range
5
1mA
0
0.1
1
Torque
4.90 to 5.88 N·m
0.78 to 0.88 N·m
4.90 to 5.88 N·m
800mW
26mA
Switching
range for
standard-
load
models
100mA 160mA
10
100
1,000
Current (mA)

Advertisement

Table of Contents
loading

Table of Contents