Miniature Limit Switch
D4CC
Many Models Including Roller Lever
Switches are Only 16-mm Thick with
Connector
• New center roller lever models that enable ganged mounting of
up to 6 Switches.
• Cable connectors for easy Switch replacement.
• Triple-seal construction for plungers to provide IEC IP67, UL,
and CSA (type 3, 4, 13) degree of protection.
• Operation indicators available for easy monitoring (standard in-
dicator is lit when Switch is not operating).
Model Number Structure
Model Number Legend
D4CC-@0@@
1
2
1. Rated Load
(These codes are different from suffix codes of the D4C)
1:
1 A at 125 VAC
2:
1 A at 125 VAC (with LED indicator)
3:
1 A at 30 VDC
4:
1 A at 30 VDC (with LED indicator)
2. Actuator
01:
Pin plunger
02:
Roller plunger
03:
Crossroller plunger
10:
Bevel plunger
24:
Roller lever
31:
Sealed pin plunger
32:
Sealed roller plunger
33:
Sealed crossroller plunger
41:
Panel mount pin plunger
42:
Panel mount roller plunger
43:
Panel mount crossroller plunger
50:
Plastic rod
60:
Center roller lever
Note: With standard models, the operation indicator turns OFF when
the switch operates. If models with operation indicators that
turn ON when the switch operates are required, add "-B" to the
end of the model number.
Miniature Limit Switch
D4CC
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron D4CC

  • Page 1 Center roller lever Note: With standard models, the operation indicator turns OFF when the switch operates. If models with operation indicators that turn ON when the switch operates are required, add "-B” to the end of the model number. D4CC...
  • Page 2: Ordering Information

    D4CC-3060 D4CC-4060 Center roller lever Note: 1. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers. 2. Refer to the following table for cable plugs. Accessories (Order Separately) Plugs Type Appearance No.
  • Page 3: Specifications

    Note: 1. The above current ratings are for steady-state current. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp loads have an inrush current of 10 times the steady-state current.
  • Page 4: Operating Characteristics

    Note: 1. The above figures are initial values. 2. The values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments.
  • Page 5 2. "Lights when not in operation" means that when the actuator is in the free position, the indicator is lit, and when the actuator is turned or pushed and the contact comes into contact with the NO side, the indicator turns OFF.
  • Page 6 (NBR) Nitrile rubber diaphragm Protective nitrile rubber cap (NBR) Built-in switch Open space (to reduce a change in internal pneumatic pressure and to prevent the res- piratory movement of the Switch.) LED indicator Connector receptacle Ground terminal Molded resin D4CC...
  • Page 7 Note: 1. All units are in millimeters unless otherwise indicated. 2. The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Ordering Information. 3. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
  • Page 8 Indicator M12 x 1 Note: 1. Operation is possible in any direction except parallel to the axis ↓. 2. The ideal range for operation is between the tip of the rod and 1/3 of the length of the actuator. D4CC...
  • Page 9 17.5 dia. x 7 Center Roller Lever stainless steel roller D4CC-@@60 40 max. 25±0.1 65.65 110.7 max. 18.9 +0.2 Two, 5.1 dia. holes (counter-sunk 10.2 dia.; depth: 6) Indicator M12 x 1 Plugs Model Cable length (L) XS2F-D421-@80-A (DC) XS2F-A421-@90-A (AC)
  • Page 10 (M5 x 0.8, length: 15) are included. +0.2 2. All the holes with 5.2 dia. must be used with M5 x 10 Allen-head bolts. 58.7±0.2 3. All the M5-tapped holes must be used with M5 hexagonal flat head bolts. 34.1 11 dia. +0.2 Four, 5.2 dia.
  • Page 11: Correct Use

    Mounting Tightening Torque Make sure that the plate to which the D4CC is mounted is flat. If the Be sure to tighten each screw to the proper tightening torque as plate is warped or has protruding parts, the D4CC may not malfunc- shown in the table.
  • Page 12 Do not expose the Switch to water exceeding 70 C or use it in steam. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.