Omron D4BS Datasheet page 8

Safety-door switch
Table of Contents

Advertisement

Other
Make sure that the D4BS is located outside the safety door and that
no metal dust, oil, or chemical will be sprayed onto the D4BS. Other-
wise, the D4BS may soon fail to operate due to the penetration of
metal dust, oil, or chemical.
Tightening Torque
Be sure to tighten each screw of the D4BS properly, otherwise the
D4BS may malfunction.
No.
Type
M3.5 terminal screw (including
1
ground terminal screw)
Cover mounting screw
2
(see note 1)
3
Head mounting screw
M5 body mounting screw
4
(see note 2)
5
Operation Key mounting screw 2.35 to 2.75 N·m
6
Connector
7
Cap screw
Note: 1. Apply a torque of 0.78 o 0.88 N·m if the D4BS is a three-con-
duit model.
2. Apply a torque of 4.90 to 5.88 N·m in the case of an Allen-
head bolt. If it is a pan head screw, apply a torque of 2.35 to
2.75 N·m.
G-150
Torque
0.59 to 0.78 N·m
1.18 to 1.37 N·m
0.78 to 0.98 N·m
4.90 to 5.88 N·m
1.77 to 2.16 N·m
1.27 to 1.67 N·m
Mounting Dimensions (M5)
Standard Model
60
30
Mounting hole
Mounting side
Insertion hole for protrusions
-0.05
5
-0.15
The D4BS can be mounted more securely by adding two protruding
portions, each of which is 5 mm maximum in height and
–0.05
5
/
mm in diameter as shown below.
–0.15
Operating Key Mounting Dimensions
Horizontal Mounting
Vertical Mounting
Adjustable Mounting (Horizontal)
Changes in Head Mounting Direction
By removing the screws on the four corners of the head, the head
can be reset in any of four directions. The head direction can be
changed with or without the Operation Key inserted in the head.
Make sure that no foreign materials penetrate through the head and
that the head is tightened securely within the proper torque range.
Safety Sensors / Components
Three-conduit Model
30
40
42
59.3±0.1
Protruding portions
27±0.1
-0.05
5
dia. holes, max. height 5
-0.15
dia. holes, max. height 5
Two, M5
20
±0.1
Two, M5
40
±0.1
Two, M5
30
±0.1

Advertisement