Engineering Data

Electrical Durability (Snap-action)
(cosj = 1)
10,000
Operating frequencies:
30 times/min., cosf = 1
5,000
125 VAC
3,000
250 VAC
480 VAC
1,000
500
300
100
Switching current (A)
Nomenclature
Head
With roller lever models, the direction of the switch head can
be varied to any of the four directions by loosening the roller
lever switch screws at the four corners of the head.
Operating Position Mark
(arrow)
The roller lever switch em-
ploys a system which allows
selection of operation on on-
ly one side (left or right)
or both sides without the
Switch Box Material
use of any tools.
Aluminum die-cast
Conduit Opening
Available in four different types of conduit threads:
Pg 13.5, G1/2 or 1/2-14NPT, M20
D4B-@N
(cosj = 0.4)
10,000
7,000
5,000
3,000
1,000
700
500
300
Push and rotate
Operating frequencies:
30 times/min., cosf = 0.4
250 VAC
500 VAC
Switching current (A)
Safety-oriented Lever Setting
Grooves which engage the lever every 90∞ are cut in the
operating position indicator plate to prevent the lever from
slipping against the rotary shaft.
Equipped with Operating Position Indicator Plate
An optimum overtravel (OT) value may be secured by
setting a desired OT value with a projection.
Shearing Force Contact Separating Mechanism
(NC Contact Section Only)
Should any abnormality occur in the contact area, the
contacts are positively pulled apart from each other by
shearing force.
Ground Terminal Screw
A ground terminal is provided to improve safety.
Contact Material
Ag alloy
G-249