Omron D4B-N Datasheet page 8

Safety limit switch
Table of Contents

Advertisement

Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
3. When placing your order, specify the conduit type by adding a code from the list below to the blank box of the following model numbers
as shown below.
Standard Switches
1: PG 13.5
2: G 1/2
3: 1/2-14NPT
4: M20
Switches
Roller Lever
safety limit switch,
mechanical form lock
D4B-##11N
Adjustable Roller Lever
D4B-##16N
Adjustable Rod Lever
D4B-##17N
G-250
3-conduit Switches
5: PG 13.5
6: G 1/2
7: 1/2-14NPT
8:
M20
17.5 dia. x 6.6 resin roller
PT 21∞ ±3∞
M5 x 12
Allen-head
31.5R
bolt
Set position
indicator
23
plate
131.3±1.2
Two, 5.3-dia.
mounting holes
Two, M4 x 12 cover
60±0.2
clamping screws
7.3
8
5.3
30±0.2
+1
40
0
19 dia. x 7
resin roller
25 to 89R
M5 x 16
Allen-
23
head bolts
Two, 5.3-dia.
mounting holes
Two, M4 x 12
60±0.2
cover clamping
screws
7.3
8
5.3
30±0.2
+1
40
0
5.4
3 dia. x 160
stainless steel
rod
145 max.
M5 x 12
Allen-head
23
bolts
Two, 5.3-dia.
mounting holes
Two, M4 x 12 cover
60±0.2
clamping screws
7.3
8
5.3
30±0.2
+1
40
0
62±1
56
16
28.3
Four, M3.5 x 24.5 head
clamping screws
22.5
11.5
99.5
77
74
Cover
15
Conduit
31.5
43
71±1
64.4
53
46.8
28.3
16
Four, M3.5 x 24.5
head clamping screws
22.5
99.5
77
74
Cover
15
Conduit
31.5
43
66±1
56.8
28.3
16
Four, M3.5 x 24.5
head clamping screws
22.5
99.5
77
74
Cover
15
Conduit
31.5
43
Safety Sensors / Components