Download Print this page

Engineering Data - Omron DZ Datasheet

Special-purpose basic switch

Advertisement

Engineering Data

■ Mechanical Durability
(Pin Plunger)
100,000
70,000
Without load
Operating frequency:
50,000
240 operations/minute
30,000
10,000
7,000
5,000
3,000
2,000
1,000
0
0.1 0.2
0.3
0.4 0.5 0.6
Overtravel (mm)
Dimensions
■ Dimensions and Operating Characteristics
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
3. The solder terminal model has a suffix "-1A" in its model number and its omitted dimensions are the same as the corresponding dimen-
sions of the pin plunger model.
Pin Plunger
DZ-10G-1B
PT
OP
+0.075
4.2
0.025
+0.1
4.36
dia.
0.05
Hinge Lever
DZ-10GW-1B
DZ-10GV-1B
PT
OP
0.7 0.8
23.3 0.25
+0.075
4.2
dia. hole
11.9
0.025
25.4 0.1
49.2
28.4
63.5R
19.7
17.7
+0.075
4.2
0.025
11.9
+0.1
4.36
dia.
25.4 0.1
0.05
49.2
t = 1 (stainless-steel lever)
63.5R
14.5
+0.075
4.2
0.025
+0.1
25.4 0.1
4.36
dia.
0.05
49.2
■ Electrical Durability
(Pin Plunger)
10,000
Operating frequency:
7,000
20 operations/minute
5,000
Overtravel: 0.13 mm
cos = 1
3,000
125 VAC cos = 1
1,000
700
500
250 VAC cos = 1
300
100
0
5
Switching current (A)
2.5SR (stainless-steel pin plunger)
3 dia.
0.4
14.5
8.2
17.45 0.2
t = 1 (stainless-steel lever)
4.9
FP
OP
14.5
*
8.2
+0.075
4.2
dia. hole
17.45 0.2
0.025
4.9
1.1
19.7
17.7
8.2
+0.075
4.2
dia. hole
11.9
0.025
17.45 0.2
Special-purpose Basic Switch
10
15
OF max.
5.59 N {570 gf}
RF min.
0.55 N {57 gf}
PT max.
1.7 mm
OT min.
0.13 mm
MD max.
0.4 mm
OP
15.6 0.4 mm
OF max.
1.67 N {170 gf}
RF min.
0.27 N {28 gf}
OT min.
1.6 mm
MD max.
4 mm
FP max.
46.3 mm
OP
21.8 1 mm
OF max.
1.96 N {200 gf}
RF min.
0.13 N {14 gf}
PT max.
6 mm
OT min.
0.4 mm
MD max.
1.7 mm
OP
18.3 1 mm
DZ