Ametek Crystal pressure XP3i Operation Manual

Ametek Crystal pressure XP3i Operation Manual

Digital test gauge (standard and dual-display(dd))
Hide thumbs Also See for Crystal pressure XP3i:

Advertisement

Quick Links

XP 3 i
Operation Manual
for XP3i Digital Test Gauge (Standard and Dual-Display(DD))
SENSORS, TEST & CALIBRATION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Crystal pressure XP3i and is the answer not in the manual?

Questions and answers

Summary of Contents for Ametek Crystal pressure XP3i

  • Page 1 XP 3 i Operation Manual for XP3i Digital Test Gauge (Standard and Dual-Display(DD)) SENSORS, TEST & CALIBRATION...
  • Page 2: Table Of Contents

    Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calibration .
  • Page 3: Overview

    Password protection to prevent Many features in this and our other products are a direct result of your comments! crystal@ametek.com. unauthorized changes Crystal Engineering is the company that designs, manufactures, markets, and services the nVision reference pressure recorder, XP3i, and 30 Series pressure •...
  • Page 4: Operating Instructions

    Overview            OPERATING INSTRUCTIONS The XP3i is shipped with batteries installed, so it’s ready to use . Press the button . The XP3i will first test all LCD segments, and then indicate on/off pressure . The XP3i always resumes operation in the mode and the units of the pressure last used, and it does not automatically rezero when turned on.
  • Page 5: Functions

    Functions  Functions Units Button Pressing this button causes the XP3i to select the next available unit of pressure measurement . Pressure Ranges, Display Scales, & Resolution on page 22 or the list of pressure units available for your model . Units that you don’t need or never use can be turned off .
  • Page 6 Functions  Resetting (Clearing) Recorded Peak Values Peak values can only be cleared when displaying either a Peak High or Peak Low recorded pressure . Press the zero button for at least ½ second . Dashed lines will briefly appear across the display indicating that both Peak values have been cleared . Both Peak High and Peak Low values will then display the current applied pressure .
  • Page 7 Functions  Tare ( -DD, Dual-Line Display XP3i Only ) Tare is a constant value subtracted from the true pressure . For instance, if you were mixing gases by partial pressure, you might want to fill a tank to 1760 psi with air, then add another 440 psi of helium .
  • Page 8 Functions  Automatic Shut-off The XP3i has a shutoff timer and will turn off automatically after 20 minutes (or the time set in CrystalControlWeb) of non-operation . Pressing any button or sending any command via the USB port resets the shutoff timer for another 20 minutes of operation . The XP3i will briefly display Auto Off 20 when turned on .
  • Page 9 Functions  Water Density (Inches of Water) The following applies only to models where inches of water is a selectable pressure unit . As shipped from the factory, the XP3i is set to display inches of water corresponding to the density of water at 4° C (39 .2° F) . You may require a different water density for your application, so the XP3i can be set to use the density of water at 20°...
  • Page 10 Functions  CrystalControlWeb software . Calibration Reminder Alert Cal Soon Enter the Cal Due date and the notification time prior . Once the defined time prior is reached, the XP3i will flash three times during the startup pro- cess . It will do this on every start-up until the calibration due date is reached, or the dates are updated . Calibration Due Alert Once the calibration due date has been reached, the XP3i has three options to choose from .
  • Page 11 Functions  Battery Replacement The XP3i uses 3 AA batteries . Loosen the four rear panel screws to gain access to the battery compartment . These four panel screws are captive inside the panel and are not remov- able . The foam gasket material inside the battery cover used to secure the batteries can make removal of the cover difficult . After all four screws have been loosened, the cover can be easily removed by prying gently on the hanging bracket with a flat head screwdriver or similar tool .
  • Page 12: Data Logging With Dataloggerxp

    Data Logging with DataLoggerXP  Data Logging with DataLoggerXP           WHAT IS DATALOGGERXP? DataLoggerXP is an optional data logging mode available for the XP3i gauge . You may purchase the DataLoggerXP option with your original order or add it later .
  • Page 13: Xp3I Dataloggerxp Operation

    Data Logging with DataLoggerXP            XP3I DATALOGGERXP GAUGE OPERATION When in data logging mode, some of the standard functionality of the standard XP3i is suspended . This includes the ability to change units . Please ensure you have the correct units selected prior to entering data logging mode .
  • Page 14 Data Logging with DataLoggerXP  Keypad Usage The following buttons and button combinations are used to control data logging runs on the XP3i . Where two keys are indicated, the operation is executed by pressing and holding down the first key, then pressing and holding down the second key until the action is completed . Note: Start by turning off the gauge .
  • Page 15 Data Logging with DataLoggerXP  Units Pressing and holding the button briefly causes the XP3i to display information about the logging state . If you continue to hold the button, a units units logging run will begin or end . Immediately after pressing the button, the gauge will display the operating mode as one of these values: units The XP3i is currently logging data .
  • Page 16 Data Logging with DataLoggerXP  Ultra Low Power (ULP) Mode The XP3i can log for extended periods with Ultra Low Power Mode, activated by the key combinations explained in Keypad Usage on page 12. Ultra Low Power Mode takes readings in Actual Mode when the recording interval is 20 minutes or longer . The letters replace the live pressure reading during a recording .
  • Page 17: Crystalcontrolweb And Crystalconnect

    Data Logging with DataLoggerXP            CRYSTALCONTROLWEB While the XP3i collects and stores the data, the CrystalControlWeb cloud software provides the interface to manage, analyze, download, and store the reports . Upload stored data from the XP3i to CrystalControlWeb (CCW) is done in one of two ways: Through Device Agent Connect to the XP3i with a standard USB cable .
  • Page 18: Serial Numbers

    Data Logging with DataLoggerXP            INFORMATION Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 580 g (20 .7 oz) (includes batteries) Housing .
  • Page 19: Bluetooth Signal

    Data Logging with DataLoggerXP            BLUETOOTH SIGNAL The XP3i’s Bluetooth signal has been optimized to be most effective directly in front of the gauge . With a direct line of sight in front of the gauge, distances of over 100 feet are possible .
  • Page 20: Specifications

    Specifications  Specifications Accuracy – Gauge Pressure Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year . Gauges must be exercised whenever exposed to significant changes in environmental conditions to achieve these specifications, and then re-zeroed . To exercise a gauge, cycle the gauge between zero (ambient barometric pressure) and the pressure of interest .
  • Page 21 Specifications  Accuracy – Absolute Pressure Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year . Gauges must be exercised whenever exposed to significant changes in environmental conditions to achieve these specifications . To exercise a gauge, cycle the gauge between zero (ambient barometric pressure) and the pressure of interest .
  • Page 22 Specifications  Media Compatibility Liquids and gases compatible with 316 Stainless Steel . The 15 psi / 16 psia versions have a Viton o-ring seal . See the CPF pressure connection below for additional details . Pressure Conversions 703 .087 millimeters of water column (water at 4° C [39 .2° F]) 1 psi = 27 .6806 inches of water column (water at 4°...
  • Page 23: Power

    Specifications            POWER Batteries . . . . . . . . . . . . . . . . . . . . . . . . Three size AA (LR6) batteries . WARNING: Do not remove or change the batteries in hazardous locations.
  • Page 24: Pressure Ranges, Display Scales, & Resolution

    Specifications            PRESSURE RANGES, DISPLAY SCALES, & RESOLUTION in H psi (abs) bar (abs) kPa (abs) Overpressure inHg mmHg kg/cm mbar 15PSI A16PSI 1BAR  A1,1BAR  100KPA  A110KPA  3 .0 x 0 .001 0 .01 0 .001 0 .01 0 .0001 0 .0001...
  • Page 25: Safety & Certifications

    Safety & Certifications  Safety & Certifications           HAZARDOUS LOCATIONS Every XP3i pressure gauge includes the following Intrinsic Safety approvals: II 1G Ex ia IIC T3...T4 Ga CSA24CA80188655X Exia Intrinsically Safe for Hazardous Locations: FTZU 23 ATEX 0015X ATEX Class I, Division 1, Groups A, B, C and D, Temperature Code T4/T3C .
  • Page 26 Safety & Certifications  FCC (US) Statements This device complies with part 15 of the FCC Rules . Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation . Any changes or modifications to the XP3i could void the user’s authority to operate the equipment .
  • Page 27: Atex/Iecex Safety Instructions

    Safety & Certifications            ATEX/IECEX SAFETY INSTRUCTIONS Bezpečnostní Instrukce Pro Prostředí s Nebezpečím Výbuchu – ČESKY (Czech) • V prostředí s nebezpečím výbuchu nepoužívejte přípojku USB . Konektor USB by měl být používán pouze v bezpečném prostředí s Um = 6 V . •...
  • Page 28 Safety & Certifications  Safety Instructions for Hazardous Locations – ENGLISH (English) • Do not use the USB connector in a hazardous location . The USB connector shall only be used in a non-hazardous location with Um = 6V . •...
  • Page 29 Safety & Certifications  Instructions De Sécurité Pour Les Zones Dangereuses – FRANÇAIS (French) • Ne pas utilisez le connecteur USB dans une Zone Dangereuse . Le connecteur USB ne doit être utilisé que dans une zone non dangereuse avec Um = 6 V . •...
  • Page 30 Safety & Certifications  Prescrizioni Di Sicurezza Per Area Pericolosa – ITALIANO (Italian) • Non utilizzare il connettore USB in Area Pericolosa . Il connettore USB deve essere utilizzato solo in un luogo non pericoloso con Um = 6 V . •...
  • Page 31 Safety & Certifications  Instrukcja Bezpieczeństwa Dla Srefy Zagrożonej Wybuchem– POLSKI (Polish) • Połączenie USB może być używane tylko poza strefą zagrożenia wybuchem . Złącze USB może być używane wyłącznie w miejscach bezpiecznych z Um = 6 V . • Wymiana baterii tylko poza strefą...
  • Page 32: Support

    Support  Support           TROUBLESHOOTING The XP3i is a very high performance gauge . Due to the high resolution of this product, you may observe conditions that appear to be defects in the product, but are in fact a result of being able to resolve and measure pressure to a degree not possible with other instruments . Noisy or Unstable Reading When Used with Fluids Err 2 Displayed When calibrating or comparing the indicated pressure from an XP3i against a hydraulic dead...
  • Page 33: Calibration

    Support            CALIBRATION Factory Adjustment If adjustment is required, we recommend returning the unit to the factory . Factory service offers benefits you won’t find anywhere else, utilizing NIST traceable standards in our A2LA accredited laboratory (#2601 .01) . Furthermore, upgrades may be available to add or enhance operating features . We designed the product to last, and we support it so that you can get the most from your investment .
  • Page 34: Software

    Support            SOFTWARE Programming Instructions The XP3i shares the same programming information as the XP2i . For more information, see the XP2i Programming Instructions. Integrate XP3is into your test environment! CrystalControlWeb Configuration Software CrystalControlWeb to disable unwanted pressure units, set default pressure units, change water density, adjust calibration, and more .  ...