Specifications - Omron 3G3JV Manual

Simple speed control compact inverters with easy-to-use functions
Hide thumbs Also See for 3G3JV:
Table of Contents

Advertisement

Specifications

Specifications
3 p
3-phase
Model 3G3JV-
200-V AC
200 V AC
Power
Rated voltage and frequency
models
models
supply
l
Allowable voltage fluctuation
Allowable frequency
fluctuation
Input power supply capacity
(kVA) (see note 1)
Heat radiation (W) (see note 2)
Weight (kg)
Cooling method
Model 3G3JV-
S g
Single-phase
p
200-V AC
200 V AC
Power
Rated voltage and frequency
models
models
supply
l
Allowable voltage fluctuation
Allowable frequency
fluctuation
Input power supply capacity
(kVA) (see note 1)
Heat radiation (W) (see note 2)
Weight (kg)
Cooling method
Note: 1. The power supply capacity, is the capacity when the Inverter is operating at its rated output. The value will vary with the
impedance at the input power supply side. (Because the power factor of the input power supply changes, the power factor
will improve if an AC reactor is inserted.) The ratio with the rated current of the motor used and the rated output current of
the Inverter will vary.
2. The "heat radiation" is the power consumed in the Inverter when it is operating at its rated output.
Max. applicable motor capacity (kW)
Output
O p
Rated output capacity (kW)
specifications
ifi
ti
Rated output current (A)
Rated output voltage (V)
Max. output frequency
C
Control
Harmonic-current countermeasures
characteristics
h
t i ti
Control method
Carrier frequency
Frequency control range
Frequency precision (temperature
characteristics)
Frequency setting resolution
Output frequency resolution
Overload capacity
External frequency set signal
Acceleration/deceleration time
Braking torque
Voltage/frequency characteristics
Protective
Motor protection
f
functions
ti
Instantaneous overcurrent protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power interruption
compensation (selection)
Cooling fin overheating
Grounding protection
Charge indicator (RUN indicator)
22
A2001
A2002
A2004
3-phase 200 to 230 V AC at 50/60 Hz
–15% to 10%
±5%
0.4
0.9
1.6
13.0
18.0
28.1
0.5
0.5
0.8
Natural cooling
AB001
AB002
AB004
Single-phase 200 to 240 V AC at 50/60 Hz
–15% to 10%
±5%
0.5
0.9
1.6
14.1
20.0
31.9
0.5
0.5
0.9
Natural cooling
0.1
0.2
0.4
0.3
0.6
1.1
0.8
1.6
3.0
3-phase 200 to 230 V AC (according to the input voltage)
400 Hz parameter setting
DC reactor (option) connection possible
Sine wave PWM (V/f control)
2.5 to 10.0 kHz (in vector control)
0.1 to 400 Hz
Digital commands: ±0.01% (–10°C to 50°C)
Analog commands: ±0.5% (25°C ± 10°C)
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz (100 Hz or over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
0.01 Hz (calculated resolution)
150% of rated output current for 1 min
Selectable with FREQ adjuster: 0 to 10 V DC (20 kΩ), 4 to 20 mA (250 Ω), and 0 to 20 mA
(250 Ω)
0.0 to 999 s (Independent acceleration and deceleration time settings)
Approx. 20%
Set a user V/f pattern
Protection by electronic thermal
Stops at approx. 250% of rated output current
Stops in 1 min at approximately 150% of rated output current
Stops when main-circuit DC voltage is approximately 410 V
Stops when main-circuit DC voltage is approximately 200 V (160 V for single-phase 200-V AC
model)
Stops for 15 ms or more. By setting the Inverter to momentary power interruption mode,
operation can be continued if power is restored within approximately 0.5 s.
Detects at 110°C ± 10°C
Protection at rated output current level
Lit when the main circuit DC voltage is approximately 50 V or less.
A2007
A2015
A2022
2.7
4.3
5.9
45.1
72.8
94.8
0.9
1.3
1.5
Cooling fan
AB007
AB015
---
2.7
4.3
---
51.4
82.8
---
1.5
1.5
---
Cooling fan
0.75
1.5
2.2
1.9
3.0
4.2
5.0
8.0
11.0
A2037
9.3
149.1
2.1
---
---
---
---
3.7
6.7
17.5