Omron 3G3JV Manual page 10

Simple speed control compact inverters with easy-to-use functions
Hide thumbs Also See for 3G3JV:
Table of Contents

Advertisement

List of Parameters
Param-
Name
eter
No.
Used to set the upper and lower frequency reference
n30
Frequency reference
upper limit
limits in percentage based on the maximum frequency
limits in percentage based on the maximum frequency
as 100%.
n31
Frequency reference
lower limit
n32
Rated motor current
Used to set the rated motor current for motor overload
detection (OL1) based on the rated motor current.
Note Motor overload detection (OL1) is disabled by set-
n33
Motor protection
Used to set the motor overload detection (OL1) for the
characteristics
electronic thermal characteristics of the motor.
n34
Motor protective
Used to set the electric thermal characteristics of the
time setting
motor to be connected in 1-minute increments.
n35
Cooling fan opera-
Used to operate the Cooling Fan of the Inverter while
tion function
the Inverter is turned on or only while the Inverter is in
operation.
Used to select the functions of multi-function input ter-
n36
Multi-function input 1
(Input terminal S2)
minals S2 through S5.
minals S2 through S5.
n37
Multi-function input 2
(Input terminal S3)
n38
Multi-function input 3
(Input terminal S4)
n39
n39
Multi-function input 4
Multi-function input 4
(Input terminal S5)
n40
Multi-function output
Used to select the functions of multi-function output
(MA/MB and MC
terminals.
output terminals)
Used to the input characteristics of analog frequency
n41
Frequency reference
gain
references.
references.
n42
Frequency reference
bias
n43
Analog frequency
Used to set the digital filter with a first-order lag for ana-
reference filter time
log frequency references to be input.
n44
Analog monitor
Used to set the output frequency or current as a moni-
output
tored item.
n45
Analog monitor
Used to set the output characteristics of analog monitor
output gain
output.
n46
Carrier frequency
Used to set the carrier frequency.
selection
n47
Momentary power
Used to specify the processing that is performed when
interruption com-
a momentary power interruption occurs.
pensation
n48
Fault retry
Used to set the number of times the Inverter is reset
and restarted automatically in the case the Inverter has
an overvoltage fault, overcurrent fault, or ground fault.
Used to set the frequency jump function.
n49
Jump frequency 1
n50
Jump frequency 2
Note
Note
n51
Jump width
n52
DC control current
U
Used to impose DC on the induction motor for braking
control.
n53
Interruption DC
control time
n54
Startup DC control
time
n55
Stall prevention
Used to select a function to change the deceleration
during deceleration
time of the motor automatically so that there will be no
overvoltage imposed on the motor during deceleration.
n56
Stall prevention level
Used to select a function to stop the acceleration of the
during acceleration
motor automatically for stall prevention during
acceleration.
n57
Stall prevention level
Used to select a function to reduce the output
during operation
frequency of the Inverter automatically for stall
prevention during operation.
n58
Frequency detection
Used to set the frequency to be detected.
level
Note: Values longer than 3 digits are rounded up to the next unit multiple.
12
Description
100%
ting the parameter to 0.0.
q
y j
p
These values must satisfy the following condi-
These values must satisfy the following condi-
tion: n49 y n50
p
C
t l
Setting
Unit of
range
setting
(see note)
0 to 110
1%
0 to 110
1%
0.0 to 120%
0.1 A
of rated out-
put current
0 to 2
1
1 to 60
1 min
0, 1
1
2 to 22
1
0 to 22
1
2 to 22
1
2 to 34
2 to 34
1
1
0 to 7, 10 to
1
17
0 to 255
1%
–99 to 99
1%
0.00 to 2.00
0.01 s
0, 1
1
0.00 to 2.00
0.01
1 to 4, 7 to
1
9
0 to 2
1
0 to 10
1
0.0 to 400
0.1 Hz
0.0 to 400
0.1 Hz
0.0 to 400
0.1 Hz
g
0 to 100
1%
0.0 to 25.5
0.1 s
0.0 to 25.5
0.1 s
0, 1
1
30 to 200
1%
30 to 200
1%
0.0 to 400
0.1 Hz
Default
Changes
Reference
setting
during op-
page
eration
100
No
16
0
No
16
Varies
No
16
with the
capacity.
0
No
16
8
No
16
0
No
16
2
No
16
5
No
16
3
No
16
6
6
No
No
16
16
1
No
17
100
Yes
17
0
Yes
17
0.10
No
17
0
No
17
1.00
Yes
17
Varies
No
18
with the
capacity.
0
No
18
0
No
18
0.0
No
18
0.0
No
18
0.0
No
18
50
No
18
0.5
No
18
0.0
No
18
0
No
18
170
No
19
160
No
19
0.0
No
19

Advertisement

Table of Contents
loading

Table of Contents