List of Parameters
Param-
Name
eter
No.
n01
Parameter
write-prohibit selection/
parameter initialization
n02
Operation mode selec-
tion
n03
Frequency reference
selection
n04
Interruption mode selec-
tion
n05
Reverse rotation-prohibit
selection
n06
STOP/RESET Key func-
tion selection
n07
Frequency selection in
local mode
n08
Key sequential
frequency setting
n09
Maximum frequency
(FMAX)
n10
Maximum voltage
(VMAX)
n11
Maximum voltage fre-
quency (FA)
n12
Middle output
frequency (FB)
n13
Middle output
frequency voltage (VC)
n14
Minimum output
frequency (FMIN)
n15
Minimum output
frequency voltage
(VMIN)
n16
Acceleration time 1
n17
Deceleration time 1
n18
Acceleration time 2
n19
Deceleration time 2
n20
S-shape acceleration/de-
celeration characteristic
n21
Frequency reference 1
n22
Frequency reference 2
n23
Frequency reference 3
n24
Frequency reference 4
n25
Frequency reference 5
n26
Frequency reference 6
n27
Frequency reference 7
n28
Frequency reference 8
n29
Inching frequency com-
mand
Note: 1. With 400-class Inverters, the default settings and maximum values setting ranges for n10, n13, and n15 are double those
given in the table.
2. Values longer than 3 digits are rounded up to the next unit multiple.
List of Parameters
Description
Used to prohibit parameters to be written, sets
parameters, or change the monitor range of
parameters.
Used to initialize parameters to default values.
Used to select the input method for the RUN and STOP
commands in remote mode.
Used to set the input method for the frequency refer-
ence in remote mode.
Used to set the stopping method for use when the
STOP command is input.
Used to select the operation with the reverse command
input.
Used to select the stop method in remote mode with
n02 for operation mode selection set to 1.
Used to set the input method for the frequency refer-
ence in local mode.
Used to enable the Enter Key for setting the frequency
reference with the Increment and Decrement Keys.
Used to set the V/f pattern as the basic characteristic of
the Inverter with output voltage per frequency set.
the Inverter with output voltage per frequency set.
Note Set the parameters so that the following condition
will be satisfied.
n14 x n12 < n11 x n09
14 x 12
11 x 09
Note The value set in n13 will be ignored if parameters
g
n14 and n12 are the same in value.
14
d 12
th
i
Acceleration time: The time required to go from 0% to
100% of the maximum frequency.
Deceleration time: The time required to go from 100%
to 0% of the maximum frequency.
Note The actual acceleration or deceleration time is ob
Note The actual acceleration or deceleration time is ob-
tained from the following formula.
Acceleration/Deceleration time = (Acceleration/De-
Acceleration/Deceleration time = (Acceleration/De-
celeration time set value) × (Frequency reference
value) ÷ (Max. frequency)
Used to set S-shape acceleration/deceleration charac-
teristics.
Used to set internal frequency references.
U
q
y
Note Frequency reference 1 is enabled in remote mode
with n03 for frequency reference selection set to 1
with n03 for frequency reference selection set to 1.
Note These frequency references are selected with mul
Note These frequency references are selected with mul-
ti-step speed references (multi-function input). See
ti-step speed references (multi-function input). See
the reference pages for the relationship between
the reference pages for the relationship between
multi-step speed references and frequency refer-
ences.
ences
Used to set the inching frequency command.
Setting
range
0, 1, 6, 8, 9
0, 1
0 to 4
0, 1
0, 1
0, 1
0, 1
0, 1
50.0 to 400
1 to 255
(see note 1)
0.2 to 400
p
l
0.1 to 399
1 to 255
(see note 1)
0.1 to 10.0
1 to 50
(see note 1)
0.0 to 999
0 to 3
0 0
0.0 to max.
frequency
f
Unit of
Default
Changes
setting
setting
during op-
(see note 2)
eration
1
1
No
1
0
No
1
0
No
1
0
No
1
0
No
1
0
No
1
0
No
1
0
No
0.1 Hz
60.0
No
1 V
200 (see
No
note 1)
0.1 Hz
60.0
No
0.1 Hz
1.5
No
1 V
12 (see
No
note 1)
0.1 Hz
1.5
No
1 V
12 (see
No
note 1)
0.1 s
10.0
Yes
10.0
Yes
10.0
Yes
10.0
Yes
1
0
No
0
0.1 Hz
6.0
No
0.0
No
0.0
No
0.0
No
0.0
No
0.0
No
0.0
No
0.0
No
6.0
No
Refer-
ence
page
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
15
15
15
15
11