Intended use
The tool is intended for collecting both wet and dry dust.
The tool is suitable for commercial use, for example in
hotels, schools, hospitals, factories, shops, offices and
rental businesses.
Power supply
The tool should be connected only to a power supply
of the same voltage as indicated on the nameplate,
and can only be operated on single-phase AC supply.
This tool should be grounded while in use to protect
the operator from electric shock. Use only three-wire
extension cords which have three-prong grounding-type
plugs and three-pole receptacles which accept the
tool's plug.
Noise
The typical A-weighted noise level determined accord-
ing to IEC60335-2-69:
Model VC1310L
Sound pressure level (L
Uncertainty (K) : 2.5 dB (A)
The noise level under working may exceed 80 dB (A).
Model VC2510L, VC3210L
Sound pressure level (L
Uncertainty (K) : 2.5 dB (A)
The noise level under working may exceed 80 dB (A).
Wear ear protection
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to IEC60335-2-69:
The vibration emission value is below 2.5 m/s

EC Declaration of Conformity

For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
VACUUM CLEANER SAFETY
WARNINGS
WARNING:
IMPORTANT! READ CAREFULLY
all safety warnings and all instructions BEFORE
USE. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
1.
Before use, make sure that this cleaner must
be used by people who have been adequately
instructed on the use of this cleaner.
2.
Before use, operators shall be provided with
information, instruction and training for the
use of the machine and the substances for
which it is to be used, including the safe
method of removal and disposal of the mate-
rial collected.
Only use the socket outlet on the cleaner for
3.
purposes specified in the instructions.
4.
If foam/liquid comes out, switch off
immediately.
5.
Clean the water level limiting device regularly
and examine it for signs of damage.
6.
Do not use the cleaner without the filter.
Replace a damaged filter immediately.
) : 72 dB (A)
pA
) : 73 dB (A)
pA
2
.
7.
USE OF EXTENSION CORD. When using an exten-
sion cord because of the great distance to your
power source, try to employ a cord that is sufficiently
thick but not too long, or cleaner performance will be
adversely affected. For outdoor applications use an
extension cord suitable for outdoor use.
VOLTAGE WARNING: Before connecting the
8.
cleaner to a power source (receptacle, outlet,
etc.) be sure the voltage supplied is the same
as that specified on the nameplate of the
cleaner. A power source with voltage greater
than that specified for the cleaner can result
in SERIOUS INJURY to the operator as well
as damage to the cleaner. If in doubt, DO NOT
PLUG IN THE CLEANER. Using a power source
with voltage less than the nameplate rating is
harmful to the motor.
9.
AVOID UNINTENTIONAL STARTING. Be sure
switch is OFF when plugging in.
10. Do not attempt to pick up flammable materials,
fire works, lighted cigarettes, hot ashes, hot
metal chips, sharp materials such as razors,
needles, broken glass or the like.
11.
NEVER USE THE CLEANER IN THE VICINITY
OF GASOLINE, GAS, PAINT, ADHESIVES OR
OTHER HIGHLY EXPLOSIVE SUBSTANCES.
The switch emits sparks when turned ON and
OFF. And so does the motor commutator during
operation. A dangerous explosion may result.
12. Never vacuum up toxic, carcinogenic, combusti-
ble or other hazardous materials such as asbes-
tos, arsenic, barium, beryllium, lead, pesticides,
or other health endangering materials.
13. Always place the cleaner on a horizontal flat
surface to prevent it from falling or moving
unintentionally.
14. Never use the cleaner outdoors in the rain.
15. For Finland, this machine is not to be used
outdoors at low temperature.
16. Do not use close to heat sources (stoves, etc.).
17. If the exhaust air is returned to the room, it
is necessary to provide for an adequate air
change rate in the room. Reference to National
regulations is necessary.
18. GUARD AGAINST ELECTRIC SHOCK. Prevent
body contact with grounded surfaces. For
example; pipes, radiators, ranges, refrigerator
enclosures.
19. Do not block cooling vents. These vents per-
mit cooling of the motor. Blockage should be
carefully avoided otherwise the motor will burn
out from lack of ventilation.
20. Keep proper footing and balance at all times.
21. DO NOT ABUSE CORD. Never carry the cleaner
by cord or yank it to disconnect from recepta-
cle. Keep cord away from heat, oil, and sharp
edges. Inspect cleaner cords periodically and
if damaged, have repaired by authorized ser-
vice facility. Inspect extension cords periodi-
cally and replace if damaged.
22. Do not fold, tug or step on the hose.
23. Stop the cleaner immediately if you notice
poor performance or anything abnormal
during operation.