Operating conditions
9 Operating conditions
9.1 Process conditions
The pressure and temperature ratings presented in this section represent the
design values for the devices. For individual applications (e.g. marine
applications with option S2x) further limitations may apply according to the
respective applicable regulations. For details see chapter Application and
industry related standards
In this chapter, all values related to pressure are gauge pressure values.
9.1.1 Process fluid temperature range
Allowed process fluid and ambient temperature ranges in hazardous areas
depend on classifications defined by applications, refer to Temperature
specification in hazardous areas
For SITRANS FC1x0 the following process fluid temperature ranges are available:
Temperature range
Standard
Medium
1)
With process connection type G2 and G6 temperature range is: -10 – 140 °C (14 – 284
°F)
9.1.2 Density
Meter size
FCS100 DN1
FCS100 DN2
FCS100 DN4
FCS100 DN6
FCS100 DN8
36 / 168
7 M E 4 4 x
-
7
5 6
1)
A5E52595189-AA, 2023/09
[}
161] under the heading Marine approvals.
[}
46].
-
8 9 10 11
12
13 14 15 16
Order code
Process fluid Design type
temperature
position 12
in °C
(°F)
-10 – 140
(14 – 284)
-10 – 140
1
(14 – 284)
-50 – 150
(-58 – 302)
-50 – 260
2
(-58 – 500)
Measuring range of density
in kg/l (lb/ft³)
0 – 5 (0 – 312)
Process conditions
-
Z
Order code
position 14
C, D, E,
F, G, H
Remote type
D, F, H