Matt
April 4, 2025
One of the wells went dead, I replaced the control module/thermostat and it still doesn’t work.
Can you help me diagnose this problem?
1 comments:
Mr. Anderson
April 4, 2025
If a SERVIT 423EST2WS well is not working after replacing the control module and thermostat, possible causes include:
1. Improper voltage – Check the power supply and rated voltage on the serial plate to verify correct connection. 2. Inadequate power supply – Running 240V equipment on a 208V connection can reduce wattage output by up to 25%, affecting performance. 3. Burned-out elements – May result from improper voltage.
Verify the power supply, voltage compatibility, and condition of the heating elements.
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 INTRODUCTION ServIt Steam Tables are designed to keep foods at optimum serving temperatures without affecting quality . They are built for tough kitchen duty with rugged stainless steel construction, heavy-duty hardware and adjustable undershelves . They are compatible with a variety of accessories (sold separately) to customize your food tables to your exact needs .
SAFETY WARNINGS ServIt Electric Steam Tables are designed, built, and sold for commercial use and should be operated by trained personnel only . Clearly post all CAUTIONS, WARNINGS, and OPERATING INSTRUCTIONS near each unit to ensure proper operation and to reduce the chance of personal injury and/or equipment damage .
USER MANUAL RECEIVING & INSPECTING THE EQUIPMENT NOTE: Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building . Visually inspect the exterior of the package and skid or container . Any damage should be noted and reported to the delivering carrier immediately .
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death . NOTE: All maintenance and repairs should be referred to the authorized representative of ServIt or to the qualified local service repairman .
USER MANUAL MAINTENANCE INSTRUCTIONS Regular Cleaning: DAILY WIPE: Purpose is to prevent the buildup of food particles, grime, and bacteria, which could affect the quality of the food and the machine's overall performance . • Turn off the machine and disconnect it from the power source . •...
USER MANUAL TROUBLESHOOTING Problem Possible Cause Possible Solution Check the power supply and rated voltage Elements burn out after Improper voltage . on the serial plate to verify the equipment is short time . connected to proper voltage . Well leak: Limescale builds up and Well leaks or drains leak causes pinholes .
This manual is also suitable for:
423est3ws423est4ws500423est4ws750423est5ws423est4wspba423est4wspbh...
Show all
Need help?
Do you have a question about the 423EST2WS and is the answer not in the manual?
Questions and answers
One of the wells went dead, I replaced the control module/thermostat and it still doesn’t work. Can you help me diagnose this problem?
If a SERVIT 423EST2WS well is not working after replacing the control module and thermostat, possible causes include:
1. Improper voltage – Check the power supply and rated voltage on the serial plate to verify correct connection.
2. Inadequate power supply – Running 240V equipment on a 208V connection can reduce wattage output by up to 25%, affecting performance.
3. Burned-out elements – May result from improper voltage.
Verify the power supply, voltage compatibility, and condition of the heating elements.