Refrigerant Cycle Diagram - Toshiba RAS-2M10G3AVG-E Service Manual

Hide thumbs Also See for RAS-2M10G3AVG-E:
Table of Contents

Advertisement

7-1. Refrigerant cycle diagram
RAS-2M10G3AVG-E, -TR
Connecting pipe
Thickness : 0,8mm
dia.9,52
Pressure
measurement
Gauge attaching port
connecting port
Packed valve
(Gas side)
(dia.9,52)
TS
NOTE :
• You need not add refrigerant if the piping length is
• Connection of only one indoor unit is unavailable. Two indoor units should be connected.

7. REFRIGERANT CYCLE DIAGRAM

Temp. measurement
T1
To
B room
Packed valve
(Gas side)
(dia.9,52)
TGb
TGa
High pressure
switch
Temp.measurement
T2
Indoor unit A
Evaporator
Cross flow fan
TA
Connecting pipe
Thickness : 0,8mm
dia.6,35
Sectional shape
of heat insulator
Pulse motor valve
TD
Compressor
KSK89D53UFZ
TE
Propeller fan
TO
Outdoor unit
NOTE :
20
m or less.
- 26 -
TC
To
B room
Packed valve
(Liquid side)
(dia.6,35)
at liquid side
(dia.1,5)
Refrigerant amount : 0.80kg (R32)
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
Per 1 unit
Max. : 15m
Min. : 2m
Total
Max. : 20m
Packed valve
(Liquid side)
(dia.6,35)