Outdoor Unit (Inverter Assembly)
Outdoor temp. sensor
A unit P.M.V.
B unit P.M.V.
MCC-1665
(Display-P.C.B)
LED
Tact-SW
Jumper
Noise filter
Input current
Sensor
Converter
(AC→DC)
Inverter
(DC→AC)
Output current
sensor
Compressor
8. CONTROL BLOCK DIAGRAM
Gas side pipe temp. sensor
Driver
circuit
of P.M.V.
Low stand by
Circuit
High power factor
correction circuit
Gate drive
circuit
Suction temp. sensor
M.C.U
・Inverter outdoor frequency control
・A/D converter function
・P.M.V control
・Processing (Temp. Processing)
・Error display
・ Serial Signal Communication with
indoor unit
・Signal Communication with MAIN-P.C.B
・Function select
Function select
Signal Communication
M.C.U
・PWM synthesis function
・Input current release control
・IPM over current detect control
・High power factor correction control
・Signal Communication with
Control-P.C.B
・Fan motor control
・Compressor motor control
・4-way valve control
・High-pressure switch
Inverter
(DC→AC)
Output current
sensor
Outdoor
fan motor
- 30 -
Evaporator temp. sensor
WP-514 (Control P.C.B)
A unit Serial Signal
Communication
circuit
B unit Serial Signal
Communication
circuit
220-240V ~50Hz
220V ~60Hz
WP-044 (MAIN P.C.B)
High-pressure switch
Clock frequency
oscillator
circuit 10MHz
Gate drive
circuit
P.M.V:Pulse motor valve
PWM :Pulse width modulation
IPM :intelligent power module
Discharge temp. sensor
For
Indoor unit
Relay circuit
4-way valve