Outdoor Unit
No. Part name
① Common
procedure
Never forget to put on the gloves at working time;
otherwise an injury will be caused by the parts etc.
1.Detachment
1) Stop operation of the air conditioner,
and turn off the main switch of the
breaker for air conditioner.
2) Remove the valve cover.
(ST2TØ4×10L 3pcs.)
• After removing screw, remove the
valve cover pulling it downward.
3) Remove the upper cabinet.
(ST1TØ4×10L 5pcs.)
• After removing screws, remove the
upper cabinet pulling it upward.
4) Remove the cord clamp.
(ST2TØ4×10L 2pcs.)
5) Remove the power supply cord and the
indoor/outdoor connecting cable from terminal.
2.Attachment
1) Attach the power supply cord and the
indoor/outdoor connecting cable to terminal.
2) Attach the cord clamp.
(ST2TØ4×10L 2pcs.)
3) Attach the upper cabinet.
(ST1TØ4×10L 5pcs.)
4) Attach the valve cover.
(ST2TØ4×10L 3pcs.)
・Set hook claws of the valve cover to square
holes (at 3 positions) of the main unit, and
attach it pushing upward.

12. HOW TO REPLACE THE MAIN PARTS

Procedure
- 78 -
Remarks
Upper cabinet
Valve cover
Screw ST1T
Screw ST2T
Terminal
cover