Maintenance By Unqualified Personnel; Service And Repairs; Troubleshooting - Igloo LUNA Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

6.2.

Maintenance by unqualified personnel

An interruption of equipment operation is recommended at least once a year in order to perform a detailed inspec- tion, check the technical condition,
correct operation and electrical wiring.
7.

SERVICE AND REPAIRS

7.1.

Troubleshooting

Refer to these Manual sections in case of any problems with starting or operation of the equipment to make sure the equipment is used properly. If the
problems persist, the hints below will help eliminate them.
Possible
Possible CAUSE
FAILURE
Mains voltage and frequency different than foreseen for the
equipment
Power supply cable disconnected
Equipment does
Power supply cable damaged
not work
Main switch on control panel is OFF
Main switch is ON, but the thermostat panel displays:
CAREL: OFF and temperature blinking alternatingly mean
Thermostat
that thermostat is off and it should be turned on
problems
IGLOO: only two dots - thermostat is off and it should be
turned on
DIXELL: OFF message: thermostat is off
Condenser contaminated
ALARMS
in
IGLOO
thermostat
Condenser fan damaged
sound alarm is
on
Ambient temperature higher than 25ºC
C0 – temperature sensor in the chamber is damaged
C1 – evaporator sensor damaged
ALARMS
on
C2 – condenser alarm sensor is dama- ged (or the second
IGLOO
thermostat
condenser sensor is damaged)
panel
E0 - temperature sensor in chamber is damaged
E1 - evaporator sensor damaged
EE -
thermostat internal error
Ed – max. defrosting time exceeded
ALARMS
on
DF – defrosting in progress (this is not an alarm)
CAREL
thermostat
L0 – low temperature alarm (lower than set temperature
panel
range inside the equipment)
HI - high temperature alarm
Pr1 – temperature sensor error inside the chamber
Pr2 – evaporator sensor error
Pr3 – condenser sensor error (if any)
LA – low temperature alarm (lower than set temperature
range inside the equipment)
ALARMY
- na
LA and AH – These alarms can be caused by
panelu
incorrect mains parameters, or incorrect placement of
termostatu
products inside the equipment.
EVCO
AH – high temperaturę alarm
AL and AH – These alarms can be caused by
incorrect power supply parameters of the electrical
network, incorrect arrangement of the goods in the
device.
IGLOO Stary Wiśnicz 289, 32-720 Nowy Wiśnicz, Tel.: +48 14/662 19 10
Suggested SOLUTION
See the rating plate. Connect the equip-
ment to correct mains
Connect the power supply cable
Remove the power supply cable from
the outlet, insulate and call authorized
service
Put the main switch to ON and check if
the thermostat is working
CAREL – Press
on thermostat
panel
IGLOO – Press
on thermostat
DIXELL – Press
on thermostat
Clean the condenser
Call authorized service
Ensure correct ambient temperature
Call authorized service
Call authorized service
Call authorized serviceserwis
Call authorized service
Call authorized serviceserwis
Wait for defrosting to end
L0 and HI – These alarms can be
caused by incorrect mains parameters.
Reset the alarms by turning the equip-
ment off using the main switch. If the
problem reoccurs (alarm is displayed
again), call authorized service!
Call authorized service
Call authorized service
Call authorized service
Sprawdzić czy towar nie zasłania, nie
Check if the products do not cover or
to- uch the temperature sensors, or do
not cover air circulation openings. Place
the product correctly and wait for 1 h.
The alarm will disappear when the
tempe- ratures return to normal values.
Reset
the
alarm
by
turning
equipment off using the main switch. If
the
problem
reoccurs
displayed
again),
call
service!
info@igloo.pl / www.igloo.pl
EN
the
(alarm
is
authorized
38