8.2.

„CAREL" thermostat

Fig.8 „CAREL" thermostat panel
LEDs ON THE DISPLAY
LED 1 on – Compressor: the symbol is visible when the compressor is running. It is blinking when the
compressor start is delayed by the protection procedure. In the continuous mode it blinks in the cycle: two blinks –
pause.
LED 2 on – Fan: the symbol is visible when the evaporator fans are on. The symbol blinks when the fan start is
delayed by an external deactivation or when another procedure is in progress.
LED 3 on – Defrosting: the symbol is visible when the defrosting procedure is activated. The symbol blinks when
the defrosting is delayed by an external deactivation or when another procedure is in progress.
LED 4 on – Alarm: the symbol is visible when an alarm is active
LED 5 on – current temperature inside the equipment (with one decimal place)
SETTING THE DESIRED TEMPERATURE
- press for 1 second :
- increase or decrease the value using
- press again
to confirm the setpoint
MANUAL DEFROSTING
Defrosting is performed automatically. You can start it manually anytime, however, by pressing and holding
for at least 5 seconds. LED 1 is blinking during the manual defrosting.
IMPORTANT: If the main switches are turned on and the display shows the word OFF and the
temperature flashing alternately, it means that the thermostat is turned off and should be turned on. Then
press the button:
located on the thermostat panel.
* More on www.alfaco.pl
IGLOO Stary Wiśnicz 289, 32-720 Nowy Wiśnicz, Tel.: +48 14/662 19 10
: the value will be displayed on the screen;
and
, until you reach the desired value;
info@igloo.pl / www.igloo.pl
EN