Igloo JSCRP Instruction Manual

Igloo JSCRP Instruction Manual

Pastry display cases

Advertisement

Instruction Manual
Pastry Display Cases
Models: JSCRP and J2SCRP
J2SCRP
JSCRP
124 Norfinch Dr. Toronto, ON. M3N 1X1
Tel : 416-663-3051 Fax : 416-663-5793
REFRIGERATION LTD.
Toll Free : 1-888-408-8819

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JSCRP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Igloo JSCRP

  • Page 1 Instruction Manual Pastry Display Cases Models: JSCRP and J2SCRP J2SCRP JSCRP 124 Norfinch Dr. Toronto, ON. M3N 1X1 Tel : 416-663-3051 Fax : 416-663-5793 REFRIGERATION LTD. Toll Free : 1-888-408-8819...
  • Page 2: Table Of Contents

    Figure 3 Mounting wire shelves........................... 6 Figure 4 Control panel............................7 Figure 5 “Carel” thermostat control panel ......................8 Figure 6 Disassembly of the front glass (JSCRP) ....................12 Figure 7 Cleaning the condenser ........................13 List of Tables Table 1 Technical data ............................4 Table 2 Table of alarms and signals ........................
  • Page 3: Unloading

    2 PROPERTIES OF THE UNIT 2.1. Purpose “JSCRP” and “J2SCRP” display cases are universal cooling devices, aimed to display and for short-term storage of confectionery goods (such as cakes, cookies, desserts… etc.) in temperatures between +1ºC and +4ºC with ambient temperature between +15ºC and +25ºC and relative air humidity not exceeding 55%, depending on the environment and the location of the unit.
  • Page 4: Technical Data

    REFRIGERATION LTD Figure 1 JSCRP and J2SCRP JSCRP (Cured glass) 1 – Stainless steel upper shelf 2 – Evaporator coil 3 – Rail (condensate outflow after defrosting the evaporator) 4 – Sliding door 5 – Inner frame 6 – Compressor 7 –...
  • Page 5: Preparing The Device For Start Up

    The equipment may be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations! ■ NEMA Plugs IGLOO refrigeration uses this type of plug. If you do not have the right outlet, have a certified electrician install the correct power source. 115/60/1...
  • Page 6: Connection And Start-Up

    REFRIGERATION LTD  High ambient temperatures will cause the compressor to overwork.  Humidity may cause rust, condensation around glass or stainless steel and decrease the efficiency of the unit. 3.3. Connection and start-up  Unpack the unit.  Place the unit on an even and hard base. Then level the unit with the levelling legs. (Figure 2) Figure 2 Leveling legs A –Screw the leg in nuts ...
  • Page 7: Unit Start Up

    REFRIGERATION LTD protective layer and components of the equipment! Any residue of adhesives or silicone on metal elements should be removed only with extraction naphtha (not applicable to items made of plastic). Do not use other organic solvents. When cleaning the unit, do not use water jet. The unit should be cleaned with a moist cloth.
  • Page 8: Temperature Regulation

    REFRIGERATION LTD  To ensure proper conditions for the stored products, do not load the shelves completely. Ensure even load of shelves and not to exceed the maximum load.  The first loading of shelves should be performed after the unit has reached the desired cooling temperature.
  • Page 9: Table 2 Table Of Alarms And Signals

    REFRIGERATION LTD Diode 1 - Compressor: This symbol is visible when the compressor is working. It blinks when compressor actuation is delayed by security procedure. It blinks in the following cycle: two blinks – pause, when the constant working mode is activated. Diode 2 - Ventilator: This symbol is visible when evaporator ventilators are turned on.
  • Page 10: Table 3 Table Of Easy Compact Parameters

    - Repeat the procedure for any other parameters that need to be modified; - Press the SET button for more than 3 s to permanently save the parameters and exit the parameter setting procedure. Table 3 Table of easy compact parameters for JSCRP and J2SCRP Par. Description Def.
  • Page 11: Maintenance

    REFRIGERATION LTD compressor and fan start delay on power-up minimum time between consecutive compressor starts minimum compressor off time minimum compressor on time compressor on time with duty setting continuous cycle duration temperature alarm bypass after continuous cycle type of defrost interval between defrosts end defrost temperature set point 12.0...
  • Page 12: Cleaning And Maintenance

    This may cause damage to the glass and is not covered by warranty. Please remove the glass with profile during cleaning. (Figure 6) Figure 6 Disassembly of the front glass (JSCRP) 1 – Front glass 2 – Upper aluminum profile (lifted guide) of the glass 3 –...
  • Page 13: Service

    REFRIGERATION LTD Figure 7 Cleaning the condenser The seller shall not be held responsible for the any condenser damages in the case of non-observance of condenser cleaning instructions. Do not use mechanical agents to quicken the defrosting process! 6. SERVICE 6.1.
  • Page 14: Service

    IGLOO Refrigeration service Telephone number: 416-663-3051 or (toll free) 1-888-408-8819 E-mail: service@igloo400.com If after checking points described in chapter 6.1 “Faults identification and repair” and the unit still does not work properly, Please Contact Technical Service @ IGLOO Refrigeration. www.igloorefrigeration.com Pastry Cases...