Checking that the fusion board has booted up correctly

When the fusion board is booting up correctly, the status LEDs follow the following sequence:
Step
1.
2.
3.
If the fusion board neither skips to the boot-loader nor starts up (no status LEDs light up):
1. Switch off the printer for approx. 10 minutes so that all components can be discharged.
2. Restart the printer.
3. If the problem still persists, contact Durst Service.
3.8.3

Checking the correct data connection

The operational data connection via the fibre optic cable to the workstation is displayed by
one of the large 3-mm Data-LEDs on the Fusion Base PCB in the Workstation and the Fusion
Base PCB on the Fusion Master Board.
 The fusion board must be booted up correctly ( Chapter 3.8.2, p. 69)
 The power LEDs must be OK
 Printer is turned on
 Workstation is turned on
2014 © Durst Phototechnik DIT GmbH, Diagnostics, Edition 09.04.2014
Status LEDs
Meaning
The top LED in the first row lights up
(LED 0.0; green) and the bottom LED in
the second row lights up (LED 1.3; red).
The bottom LED in the first row
flashes a few times (LED 0.3; green).
The bottom LED in the first row stops
flashing and stays lit continuously
(LED 0.3; green).
The bottom LEDs in both rows go out
(LED 0.3; green and LED 1.3; red).
The fusion board has booted up
correctly if only the top LED in the first
row lights up (LED 0.0; green).