3 Diagnostics
3.3

Pilz safety controller

3.3.1

Pin/LED assignment for the program LH4010P6

Fig. 3:
Overview of the Pilz safety controller
-A103 Base module
Desig-
Terminal Name
nation
X1
T0
Clocked output for security switches
T1
Clocked output for security switches
T2
Clocked output for security switches
T3
Clocked output for security switches
X2
O0
Emergency relais –Q2 (Connection
Unit)
O1
Emergency relais –Q3 (Connection
Unit)
O2
Autostart signal for unloading unit
O3
Autostart signal for feeding unit
X3
O4
Emergency Stop for ACS Controller
O5
Undervoltage circuit breaker of Q1
(Main switch)
40
2014 © Durst Phototechnik DIT GmbH, Diagnostics, Edition 09.04.2014
Description
Power relais for main supply
of UV-System
Power relais for main supply
of ACS Controller MC4U
The relay O4 is in series with
the crash sensors and the
media security switch(es)
Open contact will start a
controlled electrical brake
sequence of all axis.
Rho P10 200/250
Contact
NO
NO