Note In Connecting Single-Mode Optical Fiber Cable - Sony SUPER MOTION HDC-P43 Service Manual

Multi purpose camera
Hide thumbs Also See for SUPER MOTION HDC-P43:
Table of Contents

Advertisement

No.
Signal
5
IRIS POSI-
TION
6
UNREG
7
IRIS POSI-
TION
8
IRIS AT/MA
9
EXTENDER
ON/OFF
10
ZOOM PO-
SITION
11
FOCUS
POSI
(LENS RX)
12
FOCUS
POSI
(LENS TX)
1-3-2.
Connectors and Cables
Connection made with the connectors during installation or
service, should be made with the connectors/complete cable
assemblies specified in the following list, or equivalent parts.
Connector Name
Connectors and Cables
IN/OUT
ST connector
or ST connector single-mode fiber cable
PROMPTER OUT
Plug, BNC (Part No.: 1-794-166-41)
(BNC)
or B-B Cable assembly (1.5 m optional)
SDI 1/2
Plug, BNC (Part No.: 1-794-166-51)
(BNC)
or 5C-FB coaxial cable/ Recommendation
manufactured by Fujikura
DC IN
XLR 4-pin, Female (Part No.: 1-508-362-00)
(XLR 4-pin, Male)
or ITT Cannon XLR-4-11C equivalent
or DC cable CCDD-X2 (2 m)
LENS
Connector 12-pin, Male (Part No.:
(12-pin, Female)
1-691-190-13)
or HIROSE HR10A-10P-12P equivalent
EXT I/O
D-sub 15-pin, Male (Part No.: 1-506-582-11)
(D-sub 15-pin, Fe-
or JAE DE-15PF-N equivalent (Available
male)
shell: JAE DE-C1-J10-R equivalent)
HDC-P43
I/O
Specifications
OUT
+3.4 V (F16) to +6.2 V
(F2.8)
OUT
+10.5 to +17.0 V
IN
+3.4 V (F16) to +6.2 V
(F2.8)
OUT
AUTO IRIS: 0 V
MANU IRIS: +5 V
IN
EX 2 ON: GND
EX 0.8 ON: 30 kΩ to
GND
OFF: OPEN
EX 2 ON
EX 0.8 ON
30 kΩ
IN
WIDE: 2 V
TELE: 7V
IN
∞: 7 V
Min: 2V
OUT
1-3-3.
Note in Connecting Single-mode
Optical Fiber Cable
• When connecting the cables, turn off the power of the unit
and each equipment. Do not connect and disconnect the
cables while equipments are turned on.
• If there is dust or other contamination on the connection face
for the ST connector, transmission errors will occur. Be sure
to protect the connector with the cover when not in use.
• Connect the single-mode fiber cables as shown below so that
connecting destinations cross (IN to OUT, OUT to IN)
between this unit and the equipment.
This unit
IN
OUT
Single-mode
fiber cables (1 pair)
• It is recommendable to clean the optical contact portions of
all equipments before connecting this unit to equipments
with single-mode fiber cables.
For details on a cleaning method, refer to
Connector/Cable".