Procedure
1.
Execute automatic RPN compensation (APR) from MSU or camera.
• Execute automatic RPN compensation (APR) from MSU.
[MAINTENANCE] button → ON (lit)
Touch panel operation: [Auto Setup] → [APR]
Note
Confirm that the operation of the Auto Setup menu is enabled in the Item Permission of the MSU. (Refer to
Operation manual of MSU.)
• Execute automatic black balance adjustment (ABB) from camera to automatic RPN compensation (APR).
MENU: SERVICE
PAGE: RPN MANAGE
ITEM: AUTO CONCEAL
Note
The history information of the address data of detected RPN is updated each time APR is performed. If no RPN
is detected in consecutive five APRs, RPN is excluded from the correction target (by deleting data).
5-6-2.
Manual RPN Compensation Adjustment
When RPN is not compensated after RPN automatic compensation was performed, execute the manual RPN
compensation adjustment.
Preparation
1.
Execute RPN automatic compensation(APR).
(Refer to
"5-6-1. Automatic Compensation
Procedure
1.
Open following page by camera setup menu.
MENU: SERVICE
PAGE: MANUAL RPN
<MANUAL RPN>
RPN CH SELECT
RPN CURSOR
CURSOR H POS.
CURSOR V POS.
CURSOR JUMP
RECORD RPN
DELETE RPN
2.
Select the channel (R, G, or B) that is to be compensated.
ITEM: RPN CH SELECT → R, G, B
3.
Display the cross cursor.
ITEM: RPN CURSOR → ON
4.
Set the cross cursor center at the target RPN.
ITEM: CURSOR H POS.
ITEM: CURSOR V POS.
HDC-P43
(APR)".)
S03 TOP
:
R
:
OFF
:
1006
:
575
:
CURR
:
EXEC
:
EXEC
5-33