Instructions for the installer
3.

Electrical connection

Make sure that the voltage and capacity of the power line conform to the data shown on
the plate located under the casing. Do not remove this plate for any reason.
The plug at the end of the supply cable and the wall socket must be of the same type
and must conform to the applicable legislation on electrical installations. Make sure that
the supply line is suitably earthed.
Pass the power supply cable through the back of the unit, taking care that it does not
touch the bottom casing of the hob or the oven (if any) installed underneath it.
Fit the power line with an omnipolar circuit-breaker with a contact opening gap equal to
or greater than 3 mm, in an easily accessible position close to the appliance.
Avoid the use of adapters and shunts.
If the power cable is replaced, the cross-section of wires in the new cable must be no less
2
than 0.75 mm
(3 x 0.75 cable), remembering that the end for connection to the appliance
must have an earth wire (yellow/green) which is at least 20 mm longer. Only use a
H05V2V2-F or similar cable resistant to temperatures of up to 90°C. The replacement must
be made by a specialist technician who must implement the connection to the power grid
according to the diagram below.
L = brown
N = blue
= yellow/green
The power supply cable must be replaced by an authorised service centre to prevent
any risks.
The manufacturer cannot be held liable for damage to persons or things caused by
non-observance of the above directions or by interference with any part of the
appliance.
23