Instructions for the installer
5.

Adaptation to different types of gas

The appliance must not be built in and connected to the supply before the
following operations have been completed.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar.
If other types of gas are to be used, the nozzles must be replaced and the
primary air must be adjusted.
In order to replace the nozzles and adjust the burners, the hob top must be removed
as described below.

5.1 Removing the hob top

Remove all the burner components, following the numerical sequence in the figures
below:
Take out all the knobs by
pulling them upwards.
Lift
all
the
burner
components off the hob.
Remove
the
couvette
from
each
burner
unscrewing
the
screws.
Remove
the
fastening screws, taking
care to remove only the
screws
shown
in
figure to the right.
Having removed all the
components
described
above, lift the hob top
upwards.
by
two
hob
the
1
2
3
4
25