9. GAS CONNECTION

If the appliance is installed on an oven, you must avoid running the gas tube
round the back of the oven in order to avoid overheating.
Connection to the gas supply network can be made using a rigid copper hose or
a flexible steel hose with a continuous wall and in compliance with the guidelines
established by the applicable standard. To facilitate the connection, connector A
on the back of the appliance can be orientated laterally; loosen hexagonal nut B,
twist connector A into the desired position then retighten hexagonal nut B (it is
sealed with a rubber gasket). Once the operation is complete, check the hose
fittings for leaks using a soapy solution; never use a flame. The hob is preset for
natural gas G20 (2H) at a pressure of 20 mbar. To set it up for supply using other
types of gas, see "5. ADAPTATION TO DIFFERENT TYPES OF GAS". The gas
inlet connection is threaded ½" external gas (ISO 228-1).
Connection with a rigid copper hose: The connection
to the gas supply network must be made in such a
way that it does not cause stresses of any type on
the appliance. The connection can be made using
the adapter unit D with double cone, always inserting
gasket C (provided) in between.
Connection with a flexible steel hose: use only
continuous wall stainless steel hoses that comply
with the applicable standards, making sure to always
insert gasket C (provided) between connector A and
flexible hose E.
Installation with the flexible hose must be carried out so that the length of the
piping does not exceed 2 metres when fully extended; make sure that the hoses
do not come into contact with moving parts and that they are not crushed in any
way.