Advertisement
Vacuum Cleaner x 1
Filter x 1
Mini Brush x 1
User Manual x 1
Insert the plug into the socket, press on/off button, the machine is in vacuuming + tapping + UV mode, all indicators light up. Press on/off button again, the machine stops working
(Fig 1).
Notice: for safety reasons, the UV light only works within 3cm above object as well as less than 30 inclination degrees. Otherwise, the UV light will automatically turn off.
Notice: use water or neutral reagents to clean dust cup frequently. Make sure the filter and dust cup are frequently. Make sure the filter and dust cup are completely dry before another use.
Turn off the machine and unplug the power cord, rotate the lock knob with a coin or flatblade screwdriver from locked position to unlock position (Fig 8)
to remove the cover and roller brush to clean up (Fig 9).
After brushroll cleaning, snap the hex-gear side into the base first and press the other side. Install the cover in the reverse order of removing (Fig 10).
Notice: for safety reasons, turn off the machine and unplug power cord before cleaning brushroll.
Turn off the machine and unplug the power cord and remove the UV light cover with a cross screwdriver, wipe the UV light with dry cloth.
After cleaning, assemble parts back in reverse order.
Notice: for safety reasons, please be sure to turn off the machine and unplug the power cord before cleaning UV light in case of electric shock.
Please clean dust cup and filter after each use for further use. It is recommended to replace a filter after 30-50 hours of working time(depending on specific situation) for better use.
Any paper, lead glass, plastic will greatly affect the effect of UV light. Please wipe and clean the UV light tube regularly for better use.
Do Not touch the UV light tube as dirt will affect UV light effect.
Please check the following trouble points before go to the maintenance department.
Problems | Possible Reasons | Solution |
Power Failure | Power cord is not firmly inserted. | Insert the power cord firmly. |
No power on socket. | Check the socket. | |
On/Off button not pressed. | Press the On/Off button. | |
Low suction power | Suction port clogged. | Clean up suction port. |
Dust accumulation on filter. | Clean up the dust cup and filter. | |
Dust accumulation on cyclone. | Clean up cyclone. | |
Dust accumulation on filter. | Clean up filter. | |
UV light tube failure | The UV function is automatically off for safety reasons or weak reflection of object. | The UV function operates on the condition of less than 5CM height from the object. |
The machine operates on the same position for a long time. | Move the machine forward and backward | |
The machine is placed upright. | Machine tilted no more than 30 degrees. | |
Sensor window is contaminate. | Clean the sensor window with a half-dry cloth. | |
UV light damage. | Contact after-sale service. | |
Automatically turned off | Dust cup full. | The machine will automatically turn off to prevent the motor under long operation. If the machine automatically turned off, please clean up the dust cup and filter, unplug power cord and reuse if after 2 hours. |
Suction port clogged. | ||
Filter blocked. | ||
Brushroll failure | Brushroll tangled with foreign matter. | Remove the cover and clean up brushroll according to user guide. |
Belt broken. | Remove the cover according to user guide and check the belt. If broken, contact after-sale to repair. |
If fault remains after adopting the following solutions, contact after sale service or local distributor immediately.
Model | JV12 |
Rated voltage | 230V~ |
Rated frequency | 50Hz |
Rated power | 400W |