Culligan D1021870 Installation & Operation Manual

All purpose bottle-free cooler

Advertisement

CULLIGAN
All Purpose
Bottle-free Cooler
Featuring:
• Antimicrobial Protection
Models:
D1021870
©2010 Culligan International Com pa ny
Installation, Operation
& Service Instructions
with Parts List
®
Cat. No. 01023621
Rev. A 06/01/10
DCO # 011759
Printed in USA

Advertisement

Table of Contents
loading

Summary of Contents for Culligan D1021870

  • Page 1 Cat. No. 01023621 Rev. A 06/01/10 DCO # 011759 Installation, Operation & Service Instructions with Parts List CULLIGAN ® All Purpose Bottle-free Cooler Featuring: • Antimicrobial Protection Models: D1021870 Printed in USA ©2010 Culligan International Com pa ny...
  • Page 2: Attention Culligan Customer

    We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by con- sulting with your Culligan dealer. Untrained individuals who use this manual assume the risk of any resulting property damage or personal injury.
  • Page 3: Table Of Contents

    All Purpose ® Bottle-free Cooler Models from 2010 Contents Attention Culligan Customer: ..........ii Electrical Wiring Diagram ..........24 Key Pre-Delivery Activities ..........iv All Purpose Cooler Wetted Parts List ......25 Introduction ................ 1 All Purpose Cooler Wetted Parts Illustration ....26 All Purpose Overview ............
  • Page 4: Key Pre-Delivery Activities

    • Uses: AC50 inline post carbon filter and storage tank. • For detailed instructions about AC 50 components please refer to the complete Installation, Operation and Service Manual, Cat. No. 01018587. iv Cat. No. 01023621 Culligan® All Purpose Cooler iv...
  • Page 5 Pre-Delivery Activity: Prepare and Flush Water Treatment Components CAUTION! All RO Membranes will require a 24-hour flush to drain. All flushing of membranes and filters must be done with chlorine-free, filtered, softened water. Activity All Purpose All Purpose All Purpose All Purpose Aqua-Cleer Aqua-Cleer RO...
  • Page 6 This page intentionally left blank. vi Cat. No. 01023621 Culligan® All Purpose Cooler vi...
  • Page 7: Introduction

    Introduction Thank you for purchasing the Culligan All Purpose Cooler. The Culligan All Purpose Cooler brings a unique, fresh ap- proach and a new look to point-of-use water treatment systems in the marketplace. The system’s contemporary color scheme complements every office environment. Unlike a bottled water cooler, incoming tap water is treated as it is needed, so the water is always fresh and great tasting.
  • Page 8 Use protective clothing and proper face or eye protection equipment when handling chemicals or power tools. NOTE The Culligan All Purpose Cooler is not intended for use with water that is microbiologically unsafe or of unknown quality without adequate disinfection either before or after the system.
  • Page 9: All Purpose Overview

    All Purpose Overview All Purpose Overview Cold Tank The cold tank is manufactured from 304 Stainless Steel which is non-corrosive. The cold water temperature is preset at approximately 41°F (5°C) by the factory. The capacity of the cold tank is 1 gallon (4 liters). The cold tank temperature is controlled by a thermostat that is set at the factory.
  • Page 10: Main Parts Layout

    Main Parts Layout...
  • Page 11: Safety Information

    Safety Information Electrical Safety • Only connect the power cord to a 120V, 15A (GFI preferred) properly grounded outlet. • Never pull the power plug from the outlet with a wet hand or allow the plug to get wet. • Keep the power cord out of heavy traffic areas.
  • Page 12: Inspection And First-Time Setup Procedure

    NOTE All preparation work should be done in a clean area. A separate room is recommended. A Culligan IQR form is shipped with each unit. Fill out the IQR form and return to Culligan Quality Department. Remove the top cover of the machine. This is retained by two screws located under the front edge at the bottom of the cover and two clips in the same location.
  • Page 13 CAUTION! The unit is now live. Take suitable safety precautions. NOTE It may take several minutes before the hot tank is full and water begins to flow from the dispensing head. Flush approximately 3 gallons (11 liters) of water through the hot tank. Sanitize the Unit Slowly turn ON the water supply.
  • Page 14 18. The All Purpose Cooler should be installed within 24 hours. NOTE Prepare all filters, RO cartridges, and the RO storage tank strictly in accordance with the instructions included in the Appendix section of the manual 8 Cat. No. 01023621 Culligan® All Purpose Cooler 8...
  • Page 15: Installing The All Purpose Cooler

    Installing the All Purpose Cooler Position the Unit NOTE Per Culligan Corporate policy, you must install an external leak controller during install of the All Purpose Cooler (Part # D1018733) Locate the unit as close to an electrical connection and feedwater water supply as possible with a 3 inch (8 cm) clearance at both sides and back of the unit.
  • Page 16 Cool the water in the cold tank. When the unit has reached the set temperature, the compressor will stop running. The temperature may continue to drop as any ice that has formed on the sides of the tanks will start to melt and equalize the tank temperature. 10 Cat. No. 01023621 Culligan® All Purpose Cooler 10...
  • Page 17 Test the water temperatures. Taste the water. If you are not satisfied with the quality of the water, check the filters and flush additional water through the unit. Inspect the Unit Check the unit to make sure it is electrically safe. Check that the unit is clean and functions to the customer’s satisfaction.
  • Page 18: Operating An All Purpose Cooler

    Do not dispense water in a stop-start style of vending. Hold button continuously until cup is full). c Never try to fill more than one vessel at a time. 12 Cat. No. 01023621 Culligan® All Purpose Cooler 12...
  • Page 19: Dispensing Hot And Cold Water

    Dispensing Hot and Cold Water Dispensing Cold Water For Cold Water, press A button. The button backlight will light blue and the LED will blink. The machine will dispense cold water. Dispensing Hot Water For Hot Water, press both the B and C but- tons.
  • Page 20: Maintenance And Service

    (6% Sodium Hypochlorite) Carefully screw the bottom plug into the cartridge and insert cartridge into the left hand single head inside cooler 10. Plug in the power cord. 14 Cat. No. 01023621 Culligan® All Purpose Cooler 14...
  • Page 21 CAUTION! The unit is now live. Take suitable safety precautions. Cat. No. 01023621 Maintenance and Service...
  • Page 22: Sanitizing The All Purpose Cooler

    Install new filters. On units using RO, reconnect the carbon post filter. Plug in the power cord. CAUTION! The unit is now live. Take suitable safety precautions. Replace batteries on external leak controller. 16 Cat. No. 01023621 Culligan® All Purpose Cooler 16...
  • Page 23 Flush and Return to Service Slowly turn ON the water supply. Open the ball valve on the top of the full RO water storage tank. Flush 1–2 gallons (4–8 liters) of hot water, 1–2 gallons (4–8 liters) of cold water through the unit to flush the new water treatment components and the water in the unit.
  • Page 24: Descaling The All Purpose Cooler

    Remove all the filters from the unit and set them aside in a clean place. Place the Culligan Aqua-Cleer® sanitizing cartridge (P1020277) in the left-hand single head On units using RO, Turn off the tank ball valve, disconnect the storage tank from the product line tee and plug the tubing tee with a ¼”...
  • Page 25 NOTE When mixing the descaling solution in the empty sanitizing cartridge, try adding a little red or green food coloring to the mixture. adding food coloring will make it easier when flushing the unit later when you need to verify all descaler solution has been flushed from the unit. Remove the bottom screw plug of the sanitizer cartridge and pour 1 bag of ScaleKleen (7 oz.
  • Page 26 Taste the water. Check the unit is clean and functions to the customer’s satisfaction. If you are not satisfied with the quality of the water, check the filters and flush additional water through the unit. Answer any cus- tomer questions regarding use of the unit. 20 Cat. No. 01023621 Culligan® All Purpose Cooler 20...
  • Page 27: Troubleshooting

    Troubleshooting The following is a list of different problems that may be found while installing and operating the All Purpose Cooler. NOTE Fault finding must only be carried out by trained personnel. Symptom Possible Cause Solution NO FLOW OF WATER In this case, make sure that there is a water supply to the unit and that it is turned on.
  • Page 28: Technical Specifications

    2.51 End of Life At the end of this product’s life, please ensure that it is disposed of in an environmentally friendly manner which is fully compliant with your Country requirements/guidelines. 22 Cat. No. 01023621 Culligan® All Purpose Cooler 22...
  • Page 29: Warranty

    Warranty Limited Warranty for the CULLIGAN All Purpose Water Treatment System ® This water treatment system is guaranteed to the original user only to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase, or initial lease, but in no event longer than twenty-four (24) months from the date of manufacture.
  • Page 30: Electrical Wiring Diagram

    Ambient mode switch LED2 Hot water display Hot mode switch LED3 Cold water display Water out switch Motor for compressor Transformer Power fuse Cold thermostat Heater/Compressor switch Hot thermostat Filter timer reset switch 24 Cat. No. 01023621 Culligan® All Purpose Cooler 24...
  • Page 31: All Purpose Cooler Wetted Parts List

    Item Innowave Part Number Description BulkHead Fitting 1/4” x 1/4” O.D. 1/4” Blue Tube 1/4” Stem Elbow Connector Culligan Filter Head Culligan Filter 1 O.D. 1/4” Blue Tube Culligan Filter Head Culligan Filter 2 1/4” Stem Elbow Connector O.D. 1/4” Blue Tube 1/4”...
  • Page 32: All Purpose Cooler Wetted Parts Illustration

    All Purpose Wetted Parts Illustration Hot and Cold Figure 5. Wetted parts diagram 26 Cat. No. 01023621 Culligan® All Purpose Cooler 26...
  • Page 33: All Purpose Cooler Main Parts List

    All Purpose Main Parts List Item Innowave Description Item Innowave Description Part Number Part Number 12-5640 Top Cover, Gray Culligan Filter 2 19-1069 Thermostat for Cold Tank Stem Elbow Connector Back Panel, Gray 12-5620 Front Down Insert Panel, Gray 12-5600 Power Switch (Red) 12-5635...
  • Page 34: All Purpose Cooler Main Parts Illustration

    All Purpose Main Parts Illustration Figure 6. All Purpose model. 28 Cat. No. 01023621 Culligan® All Purpose Cooler 28...
  • Page 35: Single Head Manifold And Available Cartridges

    Single Head Manifold and Available Cartridges Part Number Description Case quantity P1020392 Single Head for Cartridges SEDIMENT FILTERS P1020258 Sediment Filter - 5 micron P1020260 Sediment Filter - 10 micron P1020262 Sediment Filter - 25 micron CARBON FILTERS P1020266 Carbon Block Filter - 5 micron P1020274 Large Carbon Block - 10 micron P1020264...

Table of Contents