Replacement Parts

1 144802
Pressure-Relief Assembly
2 154530
White Cap
3 143338
Screws for Mounting Bracket
4 151231
O-ring (OR-233)
5 155466
D-40 Filter Cartridge
6 153126
White Housing
7 150424
Housing Wrench (SW-5)
8 151242
Lead-Free Faucet (FT-10)
9 143209
Quick-Connect Tee
10 143410
Quick-Connect Union
11 144805
Quick-Connect Faucet Adapter
12 144097
Clear 3/8-inch Tubing
For replacement parts, contact your nearest retailer or callCulligan Consumer Services at 1-888-777-7962.

Performance Data

Model US-640
Important Notice: Read this performance data and compare the capabilities of this system
with your actual water treatment needs. It is recommended that, before installing a water
treatment system, you have your water supply tested to determine your actual water treat-
ment needs.
This system has been tested according to NSF/ANSI 42 and 53 for reduction of the sub-
stances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42 and 53.
D-40 Cartridge
Substance
Influent Challenge Max. Permissible Product Reduction
Concentration
Water Concentration Requirements
Standard 42 Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
Particulates at least 10,000 particles/mL
(0.5 to < 1µm) Class I
Standard 53 Health Effects
Cysts
2)
Minimum 50,000/L
Turbidity
11 ± 1 NTU
0.5 NTU
Asbestos
10
7
to 10
8
fibers/L >10
Micrometers in length
Lead 6.5 pH
0.15 mg/L ± 10%
0.010 mg/L
Lead 8.5 pH
0.15 mg/L ± 10%
0.010 mg/L
Mercury 6.5 pH 0.006 mg/L ± 10%
0.002 mg/L
Mercury 8.5 pH 0.006 mg/L ± 10%
0.002 mg/L
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
Lindane
0.002 mg/L ± 10%
0.0002 mg/L
Flow Rate = 0.6 gpm (2.27 L/min)
Capacity = 600 gallons (2271 L) or 6 months
2)
Based on the use of microspheres
Testing was performed under standard laboratory conditions, actual performance may vary.
4
5
Minimum
Average
Reduction
Reduction
≥ 50%
97%
≥ 85%
96%
99.95%
99.99%
99.99%
99.1%
99.4%
99%
99.9%
99.9%
99.3%
99.3%
94.1%
97.6%
85%
90.8%
80.6%
90%
89%
89%
92.4%
92.4%
1
2
9
6
10
NOTE: Substances reduced are not necessarily in your water. Filter must be maintained
according to manufacturer's instructions, including replacement of filter cartridges.
WARNING:
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain filterable cysts.
Contact your area retailer or local water treatment professional for replacement cartridge
pricing.
Suggested Retail Price for Replacement Filter Cartridges: D-40 $39.99
Test Conditions
Flow Rate
= 0.6 gpm
Inlet Pressure= 60 psi (4.1 bar)
pH
= 7.5 ± 1
Temperature = 68°F ± 5°F (20°C ± 2.5°C)
5
8
7
3
11
12
Operating Requirements
Pressure
= 30–125 psi (2.1-8.6 bar)
Temperature = 40–100°F (4.4–37.8°C)
Turbidity
= 5 NTU Max.