Electrical
Power Cable Specifications
1 phase
Outdoor unit
HHSM-G600005-1
HHSM-G600008-1
HHSM-G600012-1
HHSM-G600016-1
•
The power cable is not supplied with Air to water heat pump.
•
Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed
flexible cord (Code designation IEC:60245 IEC 57 / CENELEC:H05RN-F)
•
This Equipment complies with IEC 61000-3-12.
•
For the power Cable, use the grade H07RN-F or H05RN-F materials.
Communications Cable Specifications
•
If there is a risk of disturbance to the communication cable, a screened cable must be used.
Outdoor Unit terminal block Specifications
AC power : M5 Screw
During the unit installation make first the piping connections and then
electrical connections. If unit is uninstalled first disconnect electrical
28
Rated
Voltage Range
Hz
Volts
Min
50
220-240
198
50
220-240
198
50
220-240
198
50
220-240
198
Communication cable
0.75mm², 2wires
cables, then the piping connections.electrical connection.
MCA
Max
Min. Circuit Amps.
264
16 A
264
22 A
264
28 A
264
32 A
Communication: M4 Screw
MFA
Max. Fuse Amps.
20 A
27.5 A
35 A