Electrical - Samsung joule HHSM-G600005-1 Installation Manual

Table of Contents

Advertisement

Electrical

Power Cable Specifications
1 phase
Outdoor unit
HHSM-G600005-1
HHSM-G600008-1
HHSM-G600012-1
HHSM-G600016-1
The power cable is not supplied with Air to water heat pump.
Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed
flexible cord (Code designation IEC:60245 IEC 57 / CENELEC:H05RN-F)
This Equipment complies with IEC 61000-3-12.
For the power Cable, use the grade H07RN-F or H05RN-F materials.
Communications Cable Specifications
If there is a risk of disturbance to the communication cable, a screened cable must be used.
Outdoor Unit terminal block Specifications
AC power : M5 Screw
During the unit installation make first the piping connections and then
electrical connections. If unit is uninstalled first disconnect electrical
28
Rated
Voltage Range
Hz
Volts
Min
50
220-240
198
50
220-240
198
50
220-240
198
50
220-240
198
Communication cable
0.75mm², 2wires
cables, then the piping connections.electrical connection.
MCA
Max
Min. Circuit Amps.
264
16 A
264
22 A
264
28 A
264
32 A
Communication: M4 Screw
MFA
Max. Fuse Amps.
20 A
27.5 A
35 A
40 A

Advertisement