Electrical connections

Overall system configuration
Connection of the power cable (1 phase 2 wires)
Distribution board
1 phase
2 wires
220-
240V~
Or
ELCB
MCCB+
ELB
Earth
• Install cabinet panel near the outdoor unit for the convenience of service and emergency operation off.
• Make sure to install the circuit breaker with the over-current and electric leakage protection.
CAUTION

Connecting the cable

Power cable specifications
1 phase
Outdoor unit
AEX060EDEHA
f The power cable is not supplied with air conditioner.
f Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible
cord (Code designation IEC:60245 IEC 57 / CENELEC:H05RN-F)
f Equipment complying with EN/IEC 61000-3-12.
• I n case of extending the electric wire, please DO NOT use a round-shaped pressing socket.
- Incomplete wire connections can cause electric shock or a fire.
12
Outdoor unit
Communication cable
Rated
Voltage Range
Hz
Volts
Min
50
220-240
198
1 phase
2 wires
220-
240V~
Earth
MCA
Maximum
Current
Max
in normal
operation
264
20 A
Hydro unit
1 phase
2 wires
220-
240V~
DHW tank
Earth
Fuse cut-off
MFA
current
MCA1.25 +
Total fuse in
Additional Load
25 A
unit
30 A