Integra Heat Recovery Ventilation unit Installation and Wiring Instructions Stock Ref. N° 456864 220-240V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.
To mount the unit on joists: Place the unit across two beams and attach the appropriate cabling, drainage and ductwork to the unit, with the Vent-Axia logo facing up. For optimum performance, ensure the ductwork does not turn 90deg directly off the spigots. The unit should, for...
4 screws & washers provided then attach the strap-hangers onto the channel fixing holes. With the Vent-Axia logo facing down, lift by the strap-hangers and hang on the hooks on the joists in a horizontal position. The unit should, for optimum drainage, be tilted by 2 degrees towards the drain side.
Page 4
Fig. 1b. SUSPENDED IN ROOF VOID SUSPENDED CEILING STRAP-HANGERS MAINS TERMINAL BOX INTEGRA CONDENSATION DRAIN (THE UNIT SHOULD SLOPE DOWNWARDS BY 2° TOWARDS THE CONDENSATE DRAIN) Stale exhaust air from inside Fresh intake air to inside Fresh intake air from outside Stale exhaust air to outside Fig.2a (Integra operated by a Trickle/Boost switch) FAN UNIT...
Page 5
Fig.2b (Integra operated by an Ambient Response humidity sensor) FAN UNIT TERMINAL BLOCK 220-240V TRICKLE 50Hz BOOST AMBIENT RESPONSE HUMIDITY SENSOR (563501) (Not supplied) Fig.2c (Integra Controlled by a single Trickle/Boost switch via a 150VA transformer)
Page 6
Fig.2d (Integra Controlled by a single external Sensor for Trickle/Boost operation via a 150VA transformer). 1 Phase Supply (220-240V 50Hz). FUSE Switched Fused Spur Ambient Response Humidity Sensor (Not supplied 56 35 50) Ecotronic Humidity Sensor (Not supplied 56 35 32) Visionex PIR (Not supplied 45 96 23) 160V...
CLEANING INSTRUCTIONS (Cleaning to be carried out by a competent qualified person) Apart from removing odours, providing fresh air and recovering heat, this unit extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency of the unit. Therefore, to ensure peak performance, the unit should be cleaned regularly at intervals determined by the level of contamination experienced to the following procedure: (Fig.3).
Page 8
Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In thje event of any part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:- •...