Céliane
TM
400-W dimmer, all loads
1. GENERAL CHARACTERISTICS
Dimmer for controlling lighting devices. Dimmer with level memory for
switching on with the same light intensity used before switching off or
mains cut-off.
Dimmer 670 87 can be controlled via a TV or DVD, remote control (not
supplied).
240 VAC
100 VAC
Cat.
Nos
Max.
Min.
Max.
400 W
40 W
200 W
400 W
40 W
200 W
670 84
670 87
400 VA
40 VA
200 VA
400 VA
40 VA
200 VA
Caution:
Take account of transformer losses when calculating power.
Transformers must be loaded to over 60% of their power capacity.
2. RANGE
Cat.
Description
Gang
Nos
Dimmer
670 84
400 W
670 87
all loads
3. FITTING
4 0
m m
m i n
.
�
�
* not supplied with the mechanism
Technical sheet: F00544EN/01
CONTENTS
Use
Min.
20 W
Incandescent lamp
20 W
230 V halogen lamp
Halogen lamp
20 VA
with ferromagnetic
transformer
Halogen lamp
20 VA
with electronic
transformer
Connection
Weight
Characteristics
method
(g)
240/100 V
1
with screws
50
50/60 Hz
�
�
Updated: 24/03/2010
87045 LIMOGES Cedex
Telephone: +33 (0)5 55 06 87 87 - Fax: +33 (0)5 55 06 88 88
Cat. No(s): 670 84/87
CONTENTS
1. General characteristics . . . . . . . . . . . .1
2. Range . . . . . . . . . . . . . . . . . . . . . . . . .1
3. Fitting . . . . . . . . . . . . . . . . . . . . . . . . . .1
4. Overall dimensions . . . . . . . . . . . . . . .1
5. Connection . . . . . . . . . . . . . . . . . . . . .1
6. Operation . . . . . . . . . . . . . . . . . . . . . . .2
7. Technical data . . . . . . . . . . . . . . . . . . .3
8. Cleaning . . . . . . . . . . . . . . . . . . . . . . . .3
9. Conformity - Approvals . . . . . . . . . . . .3
3. FITTING
(cont'd)
1 - The mechanism is clipped to the support
2 - The rocker is clipped to the mechanism
3 - The cover plate (supplied with the rocker) is clipped to the mechanism
4 - The plate is clipped to the support
Finishes: can be fitted with the full range of Céliane finishes.
Vertical and horizontal multi-gang mounting.
4. OVERALL DIMENSIONS
45.1
5. CONNECTION
Number of terminals
Terminal type
Terminal capacity
Screwdriver
5.1 Connection of one lighting point in remplacement of a switch
N
L
(factory setting)
The phase can be connected to either terminal 1 or 2.
Page
45.1
3
With screws
2 x 1.5 mm
ou 1 x 2.5 mm
2
2
Flat-blade screwdriver 3.5 mm
or Philips No. 1 or Posidriv No. 1
or mixed size 0