Page 7
Precautions Circuit breaker trips off frequently.
Page 8
Precautions Attachment Installation must be performed by Authorized Service Center. Otherwise it may cause personal injury or damage. circuit breaker. If not, it may cause malfunction circuit breaker with suitable capacity, please...
Page 9
Precautions authorized service center in order to center only.
Page 10
Precautions Working temperature range NOTICE:...
Introduction for buttons on remote controller ( )...
Page 21
Introduction for buttons on remote controller 、...
Page 22
Introduction for buttons on remote controller Note: Function introduction for combination buttons Child lock function Temperature display switchover function...
Page 23
Replacement of batteries in remote controller NOTICE...
Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man Installation notes Maintenance notes Welding...
Page 31
Safety operation of flammable refrigerant Filling the refrigerant Safety instructions for transportation and storage...
Page 34
Safety precautions for installing and relocating the unit When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant.
Page 35
Tools for installation Note: Selection of installation location...
Installation of outdoor unit (select it according to the actual installation situation) Note: Step two: install drain joint (Only for some models) NOTE:...
Page 42
Installation of outdoor unit Step four: connect indoor and outdoor pipes Step five: connect outdoor electric wire ( )...
Page 43
Installation of outdoor unit Note: Step six: neaten the pipes Note:...
Page 44
Vacuum pumping Use vacuum pump Leakage detection...
Page 50
Specialist’s Manual The following checks shall be applied to installations using flammable refrig- erants: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
Page 51
Specialist’s Manual Checks to the refrigeration equipment Checks to electrical devices Repairs to sealed components NOTE: Repair to intrinsically safe components Cabling Detection of flammable refrigerants...
Page 54
The design and specifications are subject to change without prior notice for product improvement. Any updates to the manual will be uploaded to the service website, please check for the latest version.