AUXILIARY CONTACTS RESISTANCE TEST
RED RESET
BUTTON
BLACK RESET
BUTTON
TEST
TEST POINT
DESCRIPTION
MAIN LINE
CONTACTS
MAIN LINE
CONTACTS
MAIN LINE
CONTACTS
MAIN LINE
CONTACTS
MAIN LINE
CONTACTS
MAIN LINE
CONTACTS
AUXILIARY
TERMINAL WITH
CONTACTS
AUXILIARY
TERMINAL WITH
CONTACTS
F1 THERMAL CIRCUIT BREAKER AND
Figure F.8 – F1 thermal circuit breaker lead location
LEAD #43
LEAD #44
Table F.1 – F1 contact resistance checks
TEST POINT
1L1
2T1
3L2
4T2
5L3
6T3
1L1
2T1
3L2
4T2
5L3
6T3
TERMINAL WITH
LEAD #43
LEAD #44
TERMINAL WITH
LEAD #43
LEAD #44
1L1
5L3
3L2
1
3
5
L1
L2
L3
OFF
STOP
START
GV2ME10
F1
2
4
6
T1
T2
T3
4T2
2T1
6T3
CONDITIONS
BLACK RESET
BUTTON DEPRESSED
BLACK RESET
BUTTON DEPRESSED
BLACK RESET
BUTTON DEPRESSED
RED RESET
BUTTON DEPRESSED
RED RESET
BUTTON DEPRESSED
RED RESET
BUTTON DEPRESSED
BLACK RESET
BUTTON DEPRESSED
RED RESET
BUTTON DEPRESSED
F-19
TROUBLESHOOTING AND REPAIR
(continued)
EXPECTED
READING
ZERO OHMS
ZERO OHMS
ZERO OHMS
INFINITE OHMS
INFINITE OHMS
INFINITE OHMS
ZERO OHMS
INFINITE OHMS