Smeg CWH520D Manual page 22

Professional dishwasher
Table of Contents

Advertisement

 
 
Water pump‐out malfunction 
Err06 
Err09  Too much water in tank 
Err23  Boiler does not heat up as expected  
Err24  Boiler temperature probe malfunction 
water intake hose or cleaning of rinsing nozzles. 
If the problem persists during FILL: 
‐  tank  pressure  switch  has  failed  (continuous  empty 
reading:    check  whether  tank  safety  pressure  switch  
is tripped) 
‐ leak from pipe connected to air trap  
If the problem occurs during work cycle 
‐  filler  hose  bleeder  valve  fouled:  tank  empties 
completely  at  end  of  a  wash  cycle  due  to  siphon 
effect. 
Inspect  the  filters  for  dirt  and  check  that  the  drain 
 
hose is not blocked, bent or crushed. 
Check  that  the  drain  pump  is  not  blocked  by  dirt  by 
removing  the  insert  on  the  sump  (from  inside  the 
tank). 
If it persists, check in this order: 
‐  with  tank  empty:  constant  "tank  full"  signal:    tank 
pressure switch faulty or leak from connections of air 
trap connection pipe (water entering pipe) 
‐ with tank full: drain pump failure 
 
With tank full: 
see above (water pump‐out malfunction) 
With  tank  empty:  constant  "tank  full"  signal:  safety 
pressure switch faulty or leak from connections of air 
trap connection pipe (water entering pipe) 
The  problem  might  occur  because  water  is 
continually  entering  the  tank  (the  causes  are  as  for  
Err5 – see above) 
If it persists, check in this order: 
‐ damaged boiler heating element 
‐ contactor failure, 
‐ boiler safety thermostat failure, 
‐  boiler  temperature  probe  faulty  or  incorrectly 
positioned 
‐ motherboard relay failure, 
Important: if the boiler heating element is damaged, 
this might be due to operation with no water in the 
boiler ‐ the pressure switch is indicating full even with 
the boiler empty: check and if necessary replace the 
boiler  air  trap  and/or  the  relative  pressure  switch: 
the  problem  is  generally  preceded  by  "boiler 
overheating E28" 
boiler  temperature  probe  disconnected  or  not 
working 
‐ CWH 520 
22 