Comprehensive Distance Corrections (Ppm) - Leica TPS 1000 Series Manual

Electronic theodolites and total stations
Table of Contents

Advertisement

Comprehensive distance
corrections (ppm)
CO
IN
ID
PM
FS
SC
OC
IO
AR
RC
EG
CA
CT
BC
DF
SD
TS
IX
76
A distinction is made between atmospheric (ppm) and
geometric (ppm) corrections, the sum of which is used
as the final distance correction.
• Atmospheric correction
The atmospheric distance corrections are derived from
the dry-air temperature, air pressure or height over
mean sea-level, and relative air humidity or wet-air
temperature.
MEAS\ ATMOSPHERIC CORR.
Temperature
Atm. press.
Temp.wet-b.
ppm atmospheric
ppm geometric
ppm total
GEOM
REFRA P<>E
HELP
F1
F2
Settings for the geometrical correction.
Settings for the refraction correction.
Toggle between air pressure and height above mean
sea-level.
Toggle between relative air humidity and wet-air
temperature.
Set the atmospheric ppm to "0.00". (Individual
parameters are set to the standard atmospheric values,
corresponding to the atmospheric correction ATM=0)
The dialog is dependent on the setting within
"FUNCTIONALITY".
TPS-System 1000-2.3.1en
14:03
:
12.0
:
1013.3 mBar
:
:
:
:
%<>T' ATM=0 EDIT
F4
F3
°C
0.0
0.0
0.0
0.0
EDIT
F5
F6
© Leica

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps-system 1000Tc2003Tca2003