For TCA instruments the parameters for Automatic
Target Recognition ATR1 are assigned to the function
keys
,
,
aF...
.
ATR1 mode
This mode permits measurements to static targets.
aF...\ADDIT. FUNCTIONS
1 User template & files
2 EDM measuring program
3 Compensator/Hz-corrections
4 EDM Test (Signal/Frequency)
5 Beep / Hz-sector
6 V-Angle display
ATR
LOCK
HELP
F1
F2
Switches the automatic target recognition ON for the
ATR1-mode.
The display returns immediately to the previous dialog.
Calling the aF... - dialog again and pressing
switch the ATR1-mode OFF once more .
The operator must sight the prism coarsely using the
optical sight, so that the prism is within the field of
view.
Activating a distance measurement moves the
crosshair close to the centre of the prism with the help
of the motors, to permit a distance measurement.
If the prism is outside the sensitive area of the ATR1,
the telescope's field of view is scanned using a spiral
movement to search for the prism. Thereafter the
distance is measured.