Clean The Fluid Outlet Filters; Agitator Care - Graco SuperCat 23209 Instructions Manual

Proportioner packag
Table of Contents

Advertisement

Clean the Fluid Outlet Filters

Check the high pressure fluid outlet filters (202)
weekly. See Fig. 94.
1. Follow the Pressure Relief Procedure on page 20.
2. Unscrew the filter bowl (C) and disassemble the
filter. Refer to manual 307273, supplied.
3. Clean all parts with a compatible solvent.
4. Reassemble the filter. Refer to manual 307273.
202
C
Fig. 94
Care of the System
8339A–part

Agitator Care

1. Shut off the agitator air control valve (D). Discon-
nect the air line from the agitator.
2. Every 8 hours, add 2 to 3 drops of SAE #10 oil to
the agitator air inlet (E), to lubricate the air motor
(53a).
3. When assembling the agitator, the motor shaft (F)
and mixer shaft (53c) must not extend past the
split in the coupling (53b). Torque the coupling
screws to 23–27 in-lb (2.6–3.1 N m).
D
E
53a
F
53b
53c
Fig. 95
8337A–part

Advertisement

Table of Contents
loading

This manual is also suitable for:

Supercat 232713Supercat 23272

Table of Contents