DRAINAGE
When the heat pump unit is operating, a maximum of
approximately 300 ml of drain water is generated per
minute.
To ensure drainage, make sure to observe the following
points. Otherwise, the inside of the unit may corrode and
become damaged.
WATERPROOF THE INSTALLATION PLACE
Perform drainage construction in accordance with the
local laws and regulations so that water does not
accumulate during draining.
1 The drain hose must be constantly sloped downwards.
• Do not let it pass over the stand
• Do not let it wave
2 Make sure an outlet gap is between the drain hose
outlet and drain and indirectly drain water.
(Do not let the drain hose tip submerge)
3 Do not place the tip of the drain hose or PVC pipe
directly on the ground or bury it in the ground.
• If horizontal piping cannot be avoided, use a high
stand, and make the downward slope 1/50 or more
with a PVC pipe that has an inner diameter of 15 mm
or more.
Take measures so that the inside of the pipe does not
get clogged with foreign matter or frozen drain water.
4 Do not join the drain hose with other drainpipes, install
it on its own. (Otherwise, it may cause backflow)
RECLAIMENERGY.COM.AU
Please note that malfunctions and accidents caused by piping or
drain construction will not be covered under warranty.
Bottom board
Drain elbow
Drain hose
(Inner diameter is 15 mm or 16 mm)
Be careful not to let the drain hose
come off.
Gap*
* When installing the drain elbow, there
will be a gap between the bottom board.
If drainage is insufficient, water will leak
from this Gap.
Quick Start/Install Manual – v1.0
Provide a gap
for the spout to
indirectly drain.
(Do not let it
submerge in
water)
Install the heat pump
unit on a stand with
a height of 100 mm or
more and make the drain
hose slope downwards.