Panasonic REHP-KY-CO2-160GL Install Manual page 32

Reclaim energy heat pump hot water system
Table of Contents

Advertisement

Eg-8
Eg-9
3
Eg-10
32
Reclaim Energy |
Tank Temperature sensor not detected (open circuit)
Tank Temperature sensor fault (short circuit)
Note: Temperature control mode is disabled for Eg-8 and Eg-9 faults, however boost mode
is still operational.
Tank has not heated to 59ºC in the last 24 hours. This error will clear if the boost button is
pressed or the tank heats to 59ºC or more
This error will only appear 24 hours after any of these actions:
• The last sensor reading of 59ºC (or more), resets the timer every time this temperature
is measured
• Boost button is pressed
• There was a power up sequence
This is a good way of alerting the user if the heat pump is not heating properly