Specifications - Wavetek 2001 Instruction Manual

Sweep/signal generator
Table of Contents

Advertisement

Model
2001
GENERAL INFORMATION
TABLE 1-1. Specifications (Con't.)
band end and +16 volts t o HIGH frequency band end)
Tuning sensitivity:
16 MHzIvolt (approx.)
Sweep Width
-
Vernier 0-20 dB
O U ~ D U ~
-
External FM -
External AM
-
SWEEP SPECIFICATIONS
Sweep Modes -
Sweep time -
Horizontal Output
-
EXTERNAL LEVELING
External Monitor (ALC)
-
MARKER SPECIFICATIONS
Accuracy
-
May be controlled by a remote potentiometer. (Input and
output connections provided in Rear Panel REMOTE jack)
May be remotely programmed over a 20 dB range w i t h a
0 t o -18 volt signal. (-18 volts corresponds to a maximum
output)
Full deviation of 5250 MHz possible at rates up t o 4kHz.
With reduced deviation and linearity, modulation rates to
100kHz are possible. Sensitivity: 16 MHz/volt (approx.)
External A M signals are applied t o same connections as
for vernier 0-20 dB control. Therefore, vernier range must
be restricted so the 0 to -18 volt range is not exceeded or
distortion will occur. With average voltage set to mid-range,
100% modulation is possible t o IkHz, 40% modulation
possible to a 40kHz rate.
Repetative sweep
Single sweep
Externally triggered sweep
Manual sweep
Line lock sweep
Continuously variable from less than 10 ms t o over 100
seconds, in 4-decade steps, plus vernier
16 volts peak-to-peak (symmetrical about ground)
An external negative signal, between 0.2 and 2 volts,
may be used t o level the RF output
Birdy by-pass markers with provisions for six plug-in
marker modules, plus Front Panel external marker input.
Markers may be either single frequency or harmonic
(comb.) type.
(See Options A 1 and A2)
Model 2001
Sweep Width -
Vernier 0-20 dB
Output -
External FM -
External AM -
SWEEP SPECIFICATIONS
Sweep Modes -
Sweep time -
Horizontal Output -
EXTERNAL LEVELING
External Monitor (ALC) -
MARKER SPECIFICATIONS
Type -
Accuracy -
GENERAL INFORMATION
TABLE 1-1. Specifications (Con't.)
band end and +16 volts to HIGH frequency band end)
Tuning sensitivity:
16 MHz/volt (approx_)
May be controlled by a remote potentiometer. (Input and
output connections provided in Rear Panel REMOTE jack)
May be remotely programmed over a 20 dB range with a
o
to -18 volt signal. (-18 volts corresponds to a maximum
output)
Full deviation of ±250 MHz possible at rates up to 4kHz_
With reduced deviation and linearity, modulation rates to
100kHz are possible. Sensitivity:
16 MHz/volt (approx.)
External AM signals are applied to same connections as
for vernier 0-20 dB control. Therefore, vernier range must
be restricted so the 0 to -18 volt range is not exceeded or
distortion will occur. With average voltage set to mid-range,
100% modulation is possible to 1kHz, 40% modulation
possible to a 40kHz rate.
Repetative sweep
Single sweep
Externally triggered sweep
Manual sweep
Line lock sweep
Continuously variable from less than 10 ms to over 100
seconds, in 4-decade steps, plus vernier
16 volts peak-to-peak (symmetrical about ground)
An external negative signal, between 0.2 and 2 volts,
may be used to level the R F output
Birdy by-pass markers with provIsions for six plug-in
marker modules, plus Front Panel external marker input.
Markers may be either single frequency or harmonic
(comb.)
type.
(See Options A 1 and A2)
0.005%
1-3

Advertisement

Table of Contents
loading