INSTALLATION
M o d e l
2001
2.1.5 K-104 Rack Mounting Kit (Refer t o Figure 2 - 2 )
CONTENTS
Item
Qty.
Part No.
A
(Tray)
2 ea.
COOO-729
B (Side)
2 ea.
A500-230
C
(Screw)
1 2 ea.
HS106-905
Procedure:
Install both sides (item B ) t o one tray (item A) using
1 0 - 3 2 x 311 6" screws (item C). Position the instrument
o n the tray so that the feet extend into the provided
holes. Holes are provided for all Wavetek, Indiana 1000
and 2000 series and for most Wavetek, San Diego 130,
140, and 7 0 0 series instruments. Other instruments not
exceeding 5%'' x
8"
may also be mounted by drjlling
additional holes for their feet.
When one or both instruments are properly seated, in-
stall the other item "A" and secure w i t h the remaining
screws (item C).
NOTE: If the Wavetek instrument has been supplied
w i t h a bail, i t must be removed before installing in the
K-104 rack mounting kit.
Figure
2-2.
K-104 Rack Mounting
2.2
ELECTRICAL INSTALLATION
2.2.1 Primary Power Requirements
These instruments operate from either 11 5 volt AC or
230 volt A C supply mains as selected by a S l ~ d e Switch
located on the Rear Panel. Before operating the instru-
ment, check that the fuse mounted in the Rear Panel
Instruments are shipped from the factory for operation
Fuse Holder corresponds to the correct value for the
at 1 1 5 volt AC, 60 Hz unless specified for 230 volt AC
selected voltage; i.e., 0.5 amp for a 115 volt AC, and
or 50 Hz operation.
0.25 amp for 230 volt AC.
2.2.2 Performance Checks
The power supply has been designed to operate from
either 50 or 6 0 Hz supply mains, however, the line
The electrical performance of this instrument should be
operated sweep rate function must be adjusted to the
verified. Performance checks for incoming inspection
line frequency.
are given in Section
5,
Maintenance.
INSTALLATION
2.1.5 K-104 Rack Mounting Kit (Refer to Figure 2-2)
CONTENTS
Item
Qty.
Part No.
A (Tray)
2 ea.
COOO-729
B (Side)
2 ea.
A500-230
C (Screw)
12 ea.
HSI06-905
Procedure:
Install both sides (item B) to one tray (item A) using
10-32 x 3/16" screws (item C). Position the instrument
on the tray so that the feet extend into the provided
holes. Holes are provided for all Wavetek, Indiana 1000
and 2000 series and for most Wavetek, San Diego 130,
140, and 700 series instruments. Other instruments not
exceeding 5X." x 8" may also be mounted by drilling
additional holes for their feet.
When one or both instruments are properly seated, in-
stall the other item "A" and secure with the remaining
screws (item C).
NOTE: If the Wavetek instrument has been supplied
with a bail, it must be removed before installing in the
K-104 rack mounting kit.
2.2
ELECTRICAL INSTALLATION
2.2.1 Primary Power Requirements
These instruments operate from either 115 volt AC or
230 volt AC supply mains as selected by a Slide Switch
located on the Rear Panel. Before operating the instru-
ment. check that the fuse mounted in the Rear Panel
Fuse Holder corresponds to the correct value for the
selected voltage; i.e., 0.5 amp for a 115 volt AC, and
0.25 amp for 230 volt AC.
The power supply has been designed to operate from
either 50 or 60 Hz supply mains, however, the line
operated sweep rate function must be adjusted to the
line frequency.
2-2
Model 2001
Figure 2-2. K-104 Rack Mounting
Instruments are shipped from the factory for operation
at 115 volt AC, 60 Hz unless specified for 230 volt AC
or 50 Hz operation.
2.2.2 Performance Checks
The electrical performance of this instrument should be
verified. Performance checks for incoming inspection
are given in Section 5, Maintenance.