Wavetek 2001 Instruction Manual page 20

Sweep/signal generator
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
Model
2001
REMOTE
P L U G
I d
[SWEEP
W I D T H
CONTROL CIRCUIT
F R O N T PANEL
S W E E P WIDTH
C O N T R O L
To provide FM modulation, connect as shown at right and
set the Front Panel MODE Switch for CW operation.
TO EXTERNAL
M O D U L A T I N G
SOURCE
PERCENT
MODULATION
CONTROL
T
L S W E E P WIDTH
4
I
CONTROL
C I R C U I T
FRONT PANEL
SWEEP WIDTH
C O N T R O L
The modulating wave form should have an average poten-
tial of zero volts. Frequency sensitivity, which is approxi-
mately 16 MHzIvolt, is shown graphically in Figure 3-8.
The maximum modulating frequency, while still maintain-
ing the 16 MHzIvolt relationship, varies from approximately
4 kHz at maximum deviation t o 20 kHz for 1 MHz devia-
tion. (See Figure 3-9.) With decreased frequency sensitivity,
frequency up to 200 kHz can be used, as shown in the
shaded area of Figure 3-9 on page 3-1 1.
The peak amplitude of the modulating signal plus the DC
voltage supplied t o the Frequency Control (pin 9 of
REMOTE plug) should not exceed
+
or -16 volts. This
amplitude would program the unit to sweep beyond the
band limits.
Figure 3 8 . Program Voltage (pin 9 or 12)lFrequency
OPERATING INSTRUCTIONS
2001
REAR PANEL ...
___ ---JJ
10
=
11
EXTERNAL
SWEEP WIDTH
CONTROL
REMOTE PLUG
12
\\.... _ _ _ _ _ _
~
SWEEP WIDTH
CONTROL CIRCUIT
FRONT PANEL
SWEEP WIDTH
CONTROL
2001
TO EXTERNAL
MODULATING
SOURCE
PERCENT
MODULATION
CONTROL
REMOTE PLUG
Model 2001
REAR PANEL)l
___
~J
10
11
1\
12
\1.... _ _ _ _ _ _
~
SWEEP WIDTH
CONTROL CIRCUIT
J
lOKt
FRONT PANEL
SWEEP WIDTH
CONTROL
=
To provide FM modulation, connect as shown at right and
set the Front Panel MODE Switch for CW operation.
The modulating wave form should have an average poten-
tial of zero volts. Frequency sensitivity, which is approxi-
mately 16 MHz/volt, is shown graphically in Figure 3-8.
The maximum modulating frequency, while still maintain-
ingthe 16 MHz/volt relationship, varies from approximately
4 kHz at maximum deviation to 20 kHz for 1 MHz devia-
tion. (See Figure 3-9.) With decreased frequency sensitivity,
frequency up to 200 kHz can be used, as shown in the
shaded area of Figure 3-9 on page 3-11.
3-10
6
+1
+14
+12
+10
+8
+6
'"
C>
;'!
+4
..J
~ +2
o
~ -2
II:
~
-4
Q.
-6
-8
-10
-12
-14
-16
V
8AND 1 -0
BAND 2 -450
BAND 3 -900
./
/
/
./
50
100
150
/
V
The peak amplitude of the modulating signal plus the DC
voltage supplied to the Frequency Control (pin 9 of
REMOTE plug) should not exceed
+
or -16 volts.
This
amplitude would program the unit to sweep beyond the
band limits.
/
V
./
/
/
/
/'
./
200
250
300
700
350
400
450
500
950
1400
1150
FREQUENCY
Figure 3-8. Program Voltage (pin 9 or 12)/Frequency