CALIBRATION

After change front panel PCB in this machine, you must make calibration.
You need use tools:
Load 102 m Ohm (16.4 V/ 160 A) - for 160A version
Load 85 m Ohm (18.8 V/ 220 A) - for 220A version
Clamp A-meter with DC function
1. STEP: Connect machine on 230V/50Hz and turn ON. Display shows „SEt„
STEP: Push button „T1". Display shows „160" or „220" for 220A version. Connect
2.
machine on load (102 m ohm (16.4 V/ 160 A) or 85 m Ohm (18.8 V/ 220 A) - for 220A
version.
11