STEP: Setting max. current: Push button „T6". Connect Clamp A-meter on DC
3.
function and adjust with „ENCODER„ on value 160 AMP or 220 AMP on the clamp A-
meter. If you have right value then push „T6" button. Max. current is set.
STEP: Setting min. current: Adjust with „ENCODER„ on value 4,3 AMP (+0.5 -0) on
4.
the clamp A-meter. If you have right value then push and hold „T6" button till will be
beep. Display shows „CAL„ and after „- - -". For finish push „T1" button. Min. current is
set.
STEP: Calibration is finished. Make machine to original condition.
5.
CALIBRATION
12