When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C.
1.
power is supplied to the unit.
2.
CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by discon-
necting the unit connector.
3.
CAUTION – This is a sealed unit. Components are not replaceable. Replace the entire unit when necessary.
CAUTION – Installation and servicing should be performed by qualified personnel only. De-energize before
4.
opening.
5.
The ILB CP HE AELR is for use with grounded LED luminaires listed to UL standards. Not for use in heated
air outlets or hazardous locations.
6.
The ILB CP HE AELR requires an unswitched A.C. power source of 120 to 277 volts AC, 50/60Hz.
7.
The ILB CP HE AELR and A.C. driver must be on the same branch circuit.
8.
Do not mount near gas or electric heaters.
The ILB CP HE AELR should be mounted in locations and at heights where it will not readily be subjected to
9.
tampering by unauthorized personnel.
10.
The ILB CP HE AELR will supply 10-60VDC output at the individual rated specification for 90 minutes. See
individual units for output specifications.
11.
The ILB CP HE AELR is certified in the CA Title 20 Modernized Appliance Efficiency Database System
(MAEDBS) as a small battery charger.
12.
Suitable for use in damp locations and plenum spaces.
13.
Suitable for luminaires, recessed Type IC (intended for insulation contact).
14.
For use in 0° C minimum, 55°C maximum ambient temperatures.
15.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void
warranty, and result in non-compliance with UL specifications.
16.
Do not use this equipment for other than intended use.
17.
Install in accordance with the National Electrical Code and local regulations.
18.
Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before
final installation. See addendum for compatibility and covered luminaire requirements.
EMERGENCY LED DRIVER FOR USE
WITH LED LUMINAIRES IDENTIFIED
IN THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS
INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS
ILB CP HE AELR
"B" MOUNTING STYLE
BLUETOOTH-ENABLED EMERGENCY
LIGHTING EQUIPMENT FOR LED
HIGH EFFICIENCY PERFORMANCE
MEETS CA T20 BATTERY CHARGER
EFFICIENCY STANDARDS

Advertisement

loading

Summary of Contents for IOTA ILB CP05

  • Page 1 ILB CP HE AELR “B” MOUNTING STYLE BLUETOOTH-ENABLED EMERGENCY LIGHTING EQUIPMENT FOR LED P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 • FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS CAUTION –...
  • Page 2: Installation Instructions

    LED OUTPUT (+) LOAD DRIVER AC INPUT (120 TO 277V) BLK/WHT RED (+) BLUE (-) IOTA ILB CP HE AELR RED/WHT (+) EMERGENCY DRIVER BLUE/WHT (-) STEP 3 - INSTALL THE THREADED-BODY TEST SWITCH (TBTS) ILB CP HE AELR EMERGENCY...
  • Page 3: Completing Installation

    120-277 Line, and the WHITE wire to the Neutral. The remaining BLACK/WHITE wire must be connected to either an unswitched line, or a switched line input. SWITCHED OR BLK/WHT UNSWITCHED LINE IOTA ILB CP HE AELR WHITE EMERGENCY DRIVER COMMON BLK/ORG (120 TO 277V, 50/60HZ)
  • Page 4: Full Wiring Diagram

    LED OUTPUT (+) LOAD DRIVER AC INPUT (120 TO 277V) SWITCHED OR UNSWITCHED BLK/WHT RED (+) BLK/WHT BLUE (-) IOTA ILB CP HE AELR RED/WHT (+) EMERGENCY DRIVER WHITE UNSWITCHED BLUE/WHT (-) BLK/ORG (120 TO 277V, 50/60HZ) 24/7 POWER UNIT YELLOW...
  • Page 5 Manual Testing Table 2: TBTS Manual Test Sequences Manual Testing can be performed on the ILB CP HE AELR, provided the unit is fully charged, by pressing and releasing the TBTS. Manual Testing cannot be TEST TYPE TBTS BUTTON SEQUENCE initiated until the unit has received a full 24 hour charge.
  • Page 6 The purpose of this addendum is to sufficiently identify electrical compatibility and predictable emergency light output of the LED luminaire when used with the IOTA ILB CP Series LED emergency drivers. Verification of these operating traits does not constitute a code-compliant, as-installed emergency egress system. It is still the responsibility of the Designer/ Specifier to assure appropriate light levels are achieved during emergency operation of the luminaire in accordance with Federal, state and local municipal codes regarding path of egress illumination.