E. Frame the Fireplace
NOTICE:
+HDUWK H[WHQVLRQ GHVLJQ PXVW EH GHWHUPLQHG
EHIRUH LQVWDOODWLRQ RI ¿UHSODFH
,I WKH ¿UHSODFH LV SODFHG RQ WKH ÀRRU WKH PD[LPXP KHLJKW
RI D ¿QLVKHG UDLVHG KHDUWK LV ´ LI \RX ZDQW D KLJKHU
UDLVHG KHDUWK WKH ¿UHSODFH PXVW EH SODFHG RQ D SODWIRUP
WARNING! Risk of Fire!
DQFHV VSHFL¿HG
A minimum 1-1/2 in. (38 mm) air clearance must be
maintained at the back and 1-1/2 in. (38 mm) to the
VLGHV RI WKH ¿UHSODFH DVVHPEO\
Chimney sections at any level require a 2 in. (51 mm)
minimum air space clearance between the framing and
chimney section.
WARNING! Risk of Fire!
minimum air space clearances to combustibles. DO NOT
pack required air spaces with insulation or other materi-
als.
)LJXUH  VKRZV D W\SLFDO IUDPLQJ XVLQJ  [  OXPEHU
RI WKH ¿UHSODFH DVVXPLQJ FRPEXVWLEOH PDWHULDOV DUH
XVHG $OO UHTXLUHG FOHDUDQFHV WR FRPEXVWLEOHV DURXQG WKH
¿UHSODFH PXVW EH DGKHUHG WR 6HH )LJXUH  $Q\ IUDPLQJ
DFURVV WKH WRS RI WKH ¿UHSODFH PXVW EH DERYH WKH OHYHO RI
WKH WRS VWDQGR V
The ¿QLVKHG FDYLW\ GHSWK PXVW EH QR OHVV WKDQ  LQ
 PP IURP WKH ¿QLVKHG EDFNZDOO WR WKH RXWVLGH RI IURQW
ZDOO IUDPLQJ
DO NOT LQVWDOO KHDGHU XQWLO WKH ¿UHSODFH LV LQ SRVLWLRQ
17 in. (368 mm)
framing.
127( $IWHU URXJK LQ-
VWDOO KHDGHU ZLOO VLW RQ
WRS RI IURQW VWDQGR V
30 1/2 in.*
(772 mm)
Figure 3.11 Framing the Fireplace

Comply with all minimum clear-
You must comply with all
70 in.
61 5/8 in.
(1803 mm)
(1565 mm)
* If interior of chase will be
drywalled, add the thick-
ness to this measurement.
Heatilator • ICON I100 • 4013-263 Installers Manual • Rev S • 11/22
127( %HIRUH IUDPLQJ XS WKH FKDVH FRQVLGHU ZKHUH
DQG KRZ WKH FKLPQH\ ZLOO UXQ ,I WKHUH DUH REVWDFOHV
WKDW PLJKW EH LQ WKH ZD\ LW PD\ EH QHFHVVDU\ WR PDNH
WKH FKDVH ODUJHU WKDQ VKRZQ WR DOORZ IRU R VHWV WR EH
XVHG 5HIHU WR R VHW FKDUW RQ SDJH  LI QHHGHG
CAUTION!
Risk of Cuts/Abrasions. Wear protective gloves
and safety glasses during installation. Sheet metal edges
are sharp.
F. Secure and Level the Fireplace
7KLV ¿UHSODFH PD\ EH SODFHG RQ HLWKHU D FRPEXVWLEOH
RU QRQFRPEXVWLEOH FRQWLQXRXV ÀDW VXUIDFH )ROORZ WKH
LQVWUXFWLRQV IRU IUDPLQJ LQ 6HFWLRQ  6OLGH WKH ¿UHSODFH
LQWR SRVLWLRQ %H VXUH WR SURYLGH WKH PLQLPXP  LQ
DLU FOHDUDQFH DW WKH VLGHV DQG  LQ DW WKH EDFN RI WKH
¿UHSODFH
7KH ¿UHSODFH VKRXOG EH SRVLWLRQHG VR WKH IDFH RI WKH QRQ
FRPEXVWLEOH PDWHULDO RQ WKH ¿UHSODFH ZLOO EH ÀXVK ZLWK WKH
IDFH RI WKH GU\ZDOO RQ WKH ZDOOV
/HYHO WKH ¿UHSODFH DQG VKLP DV QHFHVVDU\
WARNING! Risk of Fire!
loose insulation.
DO NOT install against vapor barriers or exposed
insulation.
Secure insulation and vapor barriers.
Provide minimum air space clearances at the sides and
EDFN RI WKH ¿UHSODFH DVVHPEO\
1/2 in.
(13 mm)
127( $ VWUXFWXUDO KHDGHU PD\ EH SRVLWLRQHG KLJKHU XS GXULQJ
WKH HDUO\ IUDPLQJ WR KHOS ZLWK WKH LQVWDOODWLRQ RI WKH XQLW WKHQ
¿QLVK IUDPLQJ GRZQ WR FRUUHFW KHLJKW DIWHU XQLW LV VHW
Use only non-combustible
material below the top of
the front standoffs.
8 in. (203 mm) extra space
needed (both sides) for outside air
connection. If outside air duct has
no bend, this dimension may be
reduced as long as minimum
clearances are met.
Prevent contact with sagging,
Fireplace must be set out
1/2 in. (13 mm) in front of
the face of the framing
material.