Troubleshooting - Hearth & Home Pioneer-II-C Owner's Manual

Hide thumbs Also See for Pioneer-II-C:
Table of Contents

Advertisement

5
5

Troubleshooting

A. FAQs
+HDUWK
+RPH 7HFKQRORJLHV DVVXPHV QR UHVSRQVLELO-
LW\ IRU WKH LPSURSHU SHUIRUPDQFH RI WKH ¿UHSODFH V\V-
tem caused by inadequate draft due to environmental
conditions, down drafts, tight sealing construction of
the structure, or mechanical exhausting devices which
will create a negative air pressure within the structure
ZKHUH WKH ¿UHSODFH LV ORFDWHG
,I VPRNH VSLOODJH RFFXUV IURP D ¿UHSODFH RSHQLQJ ZKHQ
WKH GRRU LV RSHQ WKHUH LV HLWKHU D OHDNDJH LQ WKH ÀXH D
EORFNDJH LQ WKH ÀXH RU VRPH FRQGLWLRQ LV DIIHFWLQJ GUDIW
8QGHUVWDQGLQJ DQG GLIIHUHQWLDWLQJ WKH FRQGLWLRQV ZKLFK
can cause each of these kinds of spillage problems is
essential to their solution.
)OXH /HDNDJH
Check for improperly connected flue joints or a
GDPDJHG ÀXH MRLQW LQ WKH FKLPQH\ V\VWHP 6XFK
leakage would reduce draft (air would be drawn in
WKURXJK WKH OHDNV UDWKHU WKDQ WKURXJK WKH ¿UHSODFH 
The result might be difficult start-up and smoky
¿UHV WKDW PLJKW VSLOO LI RWKHU DGYHUVH GUDIW FRQGLWLRQV
accompany this problem.
)OXH %ORFNDJH
The damper should be open.
Check for objects that may have fallen down the
chimney.
)OXH GUDIW LV PHDVXUHG DV QHJDWLYH SUHVVXUH LQ WKH
chimney. The amount of negative pressure determines
how strong the draft is. The draft is important because
LW GUDZV WKH FRPEXVWLRQ DLU LQWR WKH ¿UHSODFH DQG SXOOV
the smoke out of the chimney.
There are three basic criteria essential in establishing
DQG PDLQWDLQLQJ ÀXH GUDIW
availability of combustion air
KHDW JHQHUDWHG IURP WKH ¿UH
GLDPHWHU DQG KHLJKW RI WKH ÀXH V\VWHP
These three factors work together as a system to create
WKH ÀXH GUDIW ,QFUHDVLQJ RU GHFUHDVLQJ DQ\ RQH RI WKHP
will affect the other two and thus change the amount of
draft in the entire system.
,I WKH ¿UH LV KDUG WR VWDUW DQG VPRNH VSLOOV RXW RI WKH ¿UH-
SODFH RU \RX ¿QG LW GLI¿FXOW WR HVWDEOLVK DQG PDLQWDLQ D
PRGHUDWHO\ KLJK EXUQ UDWH WKHQ WKH ÀXH GUDIW LV WRR ORZ
and corrective measures must be taken.
Be sure you have air available for combustion and that
\RXU ¿UHZRRG LV GU\ DQG ZHOO VHDVRQHG %XLOG \RXU ¿UHV
properly and according to the instructions given in op-
28
Hearth & Home Technologies • Pioneer-II-C Owner's Manual • 4184-900 • Rev J • 1/24
HUDWLQJ LQVWUXFWLRQV ³6WDUWLQJ D )LUH´ %H VXUH \RXU ÀXH
system is installed correctly and that it is the proper di-
ameter and height. Check for the following:
All chimney sections are properly installed.
The chimney is clean and free of creosote or soot
buildup.
Make sure overhanging trees and branches are cut
back within ten feet of the top of the chimney and the
chimney is free of debris from animals.
Ensure the chimney cap is clean and free of any
buildup of soot or creosote if cap is equipped with a
spark arrestor screen.
%H VXUH WKH FHUDPLF EODQNHW DERYH WKH EDIÀH DQG
WKH EDIÀH DUH LQ WKHLU SURSHU SRVLWLRQV
The wood being used in dry and well seasoned.
,I \RX VWLOO VXVSHFW \RX KDYH D ORZ GUDIW SUREOHP LW PD\
be necessary to increase the volume of air in your
ÀXH V\VWHP 6LQFH WKH GLDPHWHU RI \RXU ÀXH V\VWHP LV
PDWFKHG ZLWK WKH VL]H RI WKH ÀXH FROODU DQG VKRXOG QRW
be changed, then the height of the system must be in-
creased. Add chimney sections one at a time until the
draft improves.
,Q VRPH FDVHV UHJDUGOHVV RI ZKDW \RX GR LW FDQ VWLOO EH
GLI¿FXOW WR HVWDEOLVK WKH SURSHU ÀXH GUDIW 7KLV LV HVSH-
cially evident when using an exterior factory-built chim-
ney or exterior masonry chimney. Try holding a burning
UROOHG XS QHZVSDSHU DV FORVH WR WKH ÀXH RXWOHW DV SRV-
sible for a few minutes, then light the paper under the
kindling. The heat generated from the burning rolled up
newspaper should help get the draft established.
6WLOO RWKHU IDFWRUV FDQ DIIHFW KRZ ZHOO \RXU ÀXH V\VWHP
performs. Neighboring structures, high winds, tall trees,
even hillsides can affect air currents around the chim-
QH\ :HOO GHVLJQHG FKLPQH\ FDSV DUH DYDLODEOH WKDW FDQ
KHOS <RXU ¿UHSODFH GHDOHU LV WKH ORFDO H[SHUW LQ \RXU
area. He can usually make suggestions or discover
problems that can be easily corrected allowing your
¿UHSODFH WR RSHUDWH FRUUHFWO\ DV LW KDV EHHQ GHVLJQHG
providing safe and economical heat for your home.

Advertisement